Hearth Clearance -
Clearance to an
uncovered combustible
hearth
below the glass is
2 inches
. A combustible hearth
may be covered with at least ½” inch thick non
-combustible material which is placed directly below the glass. Any
combustible supporting material, such as wood studs must also be covered with ½” thick non
-combustible material.
A
non-combustible
hearth can be installed directly below glass level.
15.
Adjacent Wall
–
Distance to any side adjacent wall must be at least 7 inches from the glass.
16.
Finishing around front of the fireplace
-
Non-combustible finishing material (i.e. cement board, brick, stone, tile &
minimum
½” inch Type X fire rated
drywall
)
MUST
be used to finish around the front of the appliance. Covered
combustible material, can be used to finish around the fireplace, if the proper distance from the fireplace is maintained.
Use example below to find proper distance.
See Examples 1 & 2 below for further details.
ADJACENT WALL 7” FROM GLASS
EXAMPLE 1