Nozzle doesn’t show
correct water pattern
or show water at all
or pattern change is
delayed
Instructor view does
not show on TV
This fault can be caused by a number of factors.
Restart the nozzle controller (V2) in setup screen.
Check AAA batteries in nozzle.
Ensure tracking puck is firmly seated on nozzle.
Ensure no large RF generators or WIFI access points are too close to the
system.
Restart the SCBA.
Disable heat suit and try with only the nozzle.
Re-pair the nozzle as shown in ‘Adding New/Replacement Hardware).
Ensure the HDMI receiver is powered and shows a white or green power
light.
Ensure correct source is selected on the TV/Projector.
Move the SCBA closer to the receiver.
This system is an off the shelf video sender and is susceptible to RF
noise. Change locations or restart SCBA if picture is not restored by
trying the above.
Ensure correct power supply and USB lead are used to power the
system. Incorrect power supply can cause intermittent loss of video.
For FLAIM Trainer Duo systems, please ensure that the correct
transmitter has been selected.
Restart the SCBA
FLAIM Systems maintains a support team via email at [email protected] and
will respond within 24 hours for any further technical issues.