Instruction
Display Shows
7
The different commands can be accessed using the
F1, F2, Menu1
and
Menu2
keys.
The following is a list of the commands found under
PROG, CTRL, MV, DMV.
(Use /-1 and /+1 keys to go from one group of commands to another. Use ESC key to exit from
the displayed group of commands).
PROGRAM
NAME
MEANING
FUNCTION
AND
And
Serial connection of logical operation (A contact).
OR
Or
Parallel connection of logical operation (A contact).
NOT
Negation
LD
Load
Start operation at A (Normal open) contact.
OUT
Out
Output of the operation result.
PULS
Pulse
If input contact value changes to On status, this output will be given
during 1 Scan Time.
SET
Set
If input is turned On, the output contact is maintained with On state.
RESET
Reset
If input is turned On, the output contact is maintained with Off state.
CTRL
NAME
MEANING
FUNCTION
T
Timer
This is used to control time and is On Delay Timer.
C
Counter
This is used to count the number and is Down Counter. When the enable
signal is turned Off, the current value will be reset to the setting value.
Input after counting is finished will be ignored.
MC
Master Control Set.
MCR
MC Reset
Master Control Reset.
D
Data
Sets Data value for counter and timer.
BK
Block
END
End
Marks the end of the program.