Tip Alignment Manual
Rev C.
– June, 2015
Part Number: TA9000N
Fisnar Inc. | 19C Chapin Rd. Ste. 307, Pine Brook, NJ 07058 | T: (973) 646-5044 |
- Page 7 -
Command
Display
8
Select 3. Search Speed and input search speed
(1mm/sec ~ 3mm/sec).
Press ESC and select 1. Yes to confirm
[ Search Speed ]
Speed : 3.0 mm
9
Select 4. I/O
Input User Input number of each Axis.
See sensor input on the right for correct sensor setup.
Press ESC and select 1.Yes to confirm.
[ Set Input Mode ]
X Sensor In: 0
Y Sensor In : 1
Z Sensor In : 0
10
Select 6. Tip End
Teach position which Tip will move after Tip Align
process. Press the Enter key to register the position.
Set Tip End Pos
10
Select 2. Set Base Tip Pos.
And select 1. XYZ Pos
The Tip will Move to Start Position and start the Tip
search.
It will register the Tips position of current program.
1. Set XYZ Pos
2. Set Z Pos
11
Initial Tip Alignment setup is now complete. Proceed to
create dispensing program.
12
If Tip Position is damaged or changed, select
Menu2>2.Group Utility> 6. Auto Tip Align.
This will run the Auto Tip Alignment and all program
positions will be adjusted to the new tip position.
Tip Alignment will only affect the current program. For each program, Set Base Tip Position
must be done.
The sequence is Set Base Tip Position. -> Teaching User Program -> Running User Program ->
if Tip is exchanged, Execute Auto Tip Align.