Tip Alignment Sequence
Example. Program 0 and program 1 are using nozzle 0 with the same Set Base Tip Position.
If nozzle 0 is changed to nozzle 1,
To use program 0 => load program 0 => run Auto Tip Align.
To use program 1 => load program 1 => run Auto Tip Align.
As long as the new nozzle is activating the sensors, each program will be offset to run with
nozzle 1.
If a new program is added, must use Set Base Tip Position with nozzle 1 to get the tips initial
value. If the nozzle is changed again to nozzle 2, Tip alignment will offset each program and
correct each position.
To use program 0 => load program 0 => run Auto Tip Align.
To use program 1 => load program 1 => run Auto Tip Align.
To use program 2 => load program 2 => run Auto Tip Align.
To use program 3 => load program 3 => run Auto Tip Align.
Set Base Tip
Position
Teach User
Program
Run User
Program
If tip is
damaged or
changed,
Run Auto Tip
Alignment