2.5
Serial Number
The serial number consists of three letters and six digits and contains the following
information:
Example:
M I
M 123456
Sequential Serial Number
Manufacturing Plant Code
FISHERPAYKUL Code indicates month of manufacture
CUMBERLAND Code indicates year of manufacture
Cumberland Code
Letter C
U
M
B
E
R
L
A
N
D
Year 1
2
3
4
5
6
7
8
9
0
Fisherpaykul Code
Letter F
I
S
H
E
R
P
A
Y
K
U
L
Month 1
2
3
4
5
6
7
8
9
10
11
12
Manufacturing Plant Code
A
Laundry – Australia
F
Refrigeration – New Zealand
M
Range & Dishwasher
N
Laundry – New Zealand
Q
Refrigeration - Australia
In the example above, the appliance was manufactured in the second month of the third
year (2003) at the Range & Dishwasher plant.
2.6
Oven Cavity Fan (Convection Fan)
Note:
The oven cavity fan should always run when the fan element is on.
The fan will start 8 seconds after an Aero Oven Mode has been selected.
Operational Modes:
True Aero
Aero Bake
Aero Pastry
Aero Broil / Grill
Self-Clean
Roast (first 20min only)
Voltage:
240
VAC
Wattage:
35 watts
Frequency:
60
HZ