517792A
34
40.
(00101000) Basket Dis-engage Fault
While carrying out a basket check, the Motor Control Module has found that the basket is
not engaged even though the pressure sensor indicates that the basket is empty. The
Motor Control Module continues to check for 2 minutes, after which time it displays this
fault. The first two areas to check are the clutch and the pressure tube. If these two
appear correct, then the fault could be in the pressure sensor in the Motor Control Module.
Primary Source:
Mechanical.
Action:
1) Check that there are no clothes or other foreign objects preventing
the clutch from re-engaging. Excessive suds can stop the basket
rotating.
2) If the machine is empty of water, carry out a clutch disassembly
procedure and check the spline drive.
3) Next check that the pressure tube has not come off and that it is
not kinked.
Secondary Source:
Motor Control Module.
Action:
Replace Motor Control Module.
41.
(00101001) Temperature Sensor Fault (Thermistor)
The temperature sensor is measuring temperatures above 230
o
F / 110
o
C. The fault is
probably due to a short circuit in the sensor line. This fault is only applicable in the GW
models.
Primary Source:
Thermistor.
Action:
1) Check the connection from the thermistor the Motor Control
Module
2) Check the resistance of the thermistor. Resistance should be 10k
W
@ 77
o
F / 25
o
C or 12.5k
W
@ 68
o
F / 20
o
C. Replace if faulty.
3) Replace the Motor Control Module.
45.
(00101101) Display Memory Check Fault
On power up, the display has checked its memory against a known reference and found
differences.
Primary Source:
Display Module.
Action:
Replace Display Module.
46.
(00101110) Display Memory EEPROM Check
The Intuitive™ Display has detected a problem with its internal EEPROM.
Primary Source:
Display Module.
Action:
Replace Display Module.
48.
(00110000) Hot and Cold Valve Coil Faulty
The Motor Controller module has measured voltages from the valve diagnostic
circuit that indicate both the hot and cold valves are faulty. The most likely cause is
that the valve harnesses have not been connected correctly or the valve is open
circuit.
Primary Source:
Wiring.
Action:
Check the valve harnesses are correctly fastened to the valves or the
pins are not bent backwards.
Secondary Source:
Water Valves.
Action:
Check the valve coils are not faulty (open circuit).
Tertiary Source:
Motor
Controller
module.
Action:
Replace the Motor Controller module.