Tables
Page VI Panda_12mini_PMS_Digital_s00865_Installation manual.V02 - Chapter E: Tables
23.1.07
IMPORTANT FOR THREEPHASE GENERATORS!
The cable cross-section must be arranged at three-
phase generators, if load of the generator is asymme-
tric!
E.2 Technical data
Panda 12mini PMS Digital 120V/60Hz
Type
Kubota D 722
Govenor
VCS
Automatic Startbooster
yes
No. cylinder
3
Bore
67mm
Stroke
68mm
Stroke volume
719cm
3
max. power (SAEJ1349) at 3600rpm
12,15kW
Rated speed
3600rpm
Idle running speed
a
a.
progressive govenor by VCS
3510rpm
Lubrication oil capacity
3,8l
Fuel consumption
b
b.
0,35l/kW electrical power, the randomized values between 30% and 80% of the power rating
ca. 1,1 - 2,94l
Oil consumption
max. 1% of fuel consumption
Cooling water requirement for raw water circuit
16-28l/min
Da
240mm
Di
135mm
Lfe
120mm
Ohmic resistance
H1/H2: 0,2 Ohm; Z1/Z2: 0,5 Ohm
Inductive resistance
H1/H2: 0,5 mH; Z1/Z2: 3,5 mH
Capacitors
Booster: 2x40µF
Excitation: 4x50µF