Tables
23.1.07
Panda_12mini_PMS_Digital_s00865_Installation manual.V02 - Chapter E: Tables Page V
Table 1: Voltage values stator coil
Terminal
Panda 12mini
4 - 2 (60Hz)
~ 3-5 Volt
Table 2: Diameter of conduits
Generator type
Ø Cooling water conduit
Ø Exhaust con-
duit
[mm]
Ø Fuel conduit
Frehwater
[mm]
Raw water
[mm]
Supply
[mm]
Return
[mm]
Panda PMS 12mini
20
20
40
8
8
Table 3: Rated current
Panda 12mini - 120 V / 60 Hz
43 A
Table 4: Cable cross-section
Wiring for vehicles.
Single phase, not tin plated, PVC-insulated.
Nominal conductor cross-
section
[mm²]
Allowed continuous current (guidance level)
a
a.
According to DIN VDE 0298, part 4.
at +30°C [A]
at +50°C [A]
1
19
13,5
1,5
24
17,0
2,5
32
22,7
4
42
29,8
6
54
38,3
10
73
51,8
16
98
69,6
25
129
91,6
35
158
112
50
198
140
70
245
174
95
292
207
120
344
244
Summary of Contents for Panda 12 mini PMS Digital