Mode of Operation of the Generator
Page 6 Panda_12mini_PMS_Digital_s00865_Installation manual.V02 - Chapter A: Mode of Operation of the Generator
23.1.07
Thermo-switch in the generator coil
1. Generator coil
2. Thermo-switch 4x165°C/175°C
3. Housing
For the protection of the generator coil
there are two thermo-switches inside the
coil, which are for inserted parallel and
safety's sake independently from each
other.
Fig. A.2: Coil thermo-switch
Thermo-switch at the front plate
The generator bearing is equipped with an
thermoswitch, which switches the engine
off if the temperature becomes to high.
130°C
Fig. A.3: Thermo-switch at front plate
Thermo-switch at water-cooled
exhaust elbow
120°C/105°C at 120V/60Hz
Fig. A.4: Thermo-switch at exhaust elbow
1
3
2
Summary of Contents for Panda 12 mini PMS Digital