Maintenance Instructions
Page 24 Panda_12mini_PMS_Digital_s00865_Installation manual.V02 - Chapter B: Maintenance Instructions
23.1.07
B.6.1 Draining the coolant
In principle only describes here, how the cooling water of the raw water cycle can be drained. The
mixture of the fresh water circuit should not be drained in principle. See measures for the prepa-
ration of the winter storage.
The simplest and cleanest method consists of the fact to bring the external vent valve below the
generator level and hold over a collecting basin. Open the valve now, the water from the raw
water circuit flows downward into the container.
B.7
Exchange of the v-belt
for the internal cooling water pump
The relative high ambient temperature in the closed sound insulated capsule (about 85°C) can be
a reason for a reduced lifespan of the v-belts. It is possible that the "softener" in the rubber com-
pound lose their effect after a short operating time because the air in the sound insulated capsule
can be relative warm and dry. The v-belt must be controlled in a very short time interval. It can be
happen to change the v-belt after some weeks because of unfavorably conditions. Therefore the
control is needed in an interval of 100 operating hours. The v-belt ia a wearing part. It should be
enough spare v-belts on board. We suggest to stand by the according service-packet.
Loosen the fixing screw above the alterna-
tor.
Fig. B.22: Fixing screw alternator
Loosen the fixing screw below the alterna-
tor only a little bit.
Fig. B.23: Fixing screw alternator
13
13