Copyright 2014 Firstech, LLC.
Page 3
Copyright 2014 Firstech, LLC.
Page 3
Copyright 2014 Firstech, LLC.
Page 29
CM7200
Master Guide
Starter System
techfeed.compustar.com
1-02 Door Lock/Unlock Pulse Duration: This does not affect the behavior of the factory arm output (orange
wire) or factory alarm disarm output (orange/white wire).
FO1 - 0.8 seconds:
(-) Negative lock and unlock output time.
FO2 - 2.5 seconds:
(-) Negative lock and unlock output time.
FO3 - 0.125 seconds:
(-) Negative lock and unlock output time. This option may be helpful when
using lock/unlock to arm/disarm vehicles that may roll windows down with factory Arm/Disarm wires
when the standard output is too long.
FO4- 3.5 seconds:
(-) Negative lock and unlock output time.
1-03 Driver’s Priority Unlock:
FO1 - Off:
(default)
FO2 - On:
This feature will allow the user to unlock the driver’s door first. If the unlock button is
pressed again within 4 seconds, the other doors will unlock. The driver’s door unlock must be isolated
from the other doors and use the blue (-) unlock. The Orange/Black (-) 2nd unlock (POC setting) is
used to provide unlock output to unlock all other doors.
1-04 Double Pulse Unlock:
FO1 - Off:
(default)
FO2 - Unlock:
This option will provide a double pulse output
only
for unlock each time the CM7
executes the unlock command. (Length of output time will be based on feature 1-02 option settings.)
FO3 - Lock:
This option will provide a double pulse lock output
only
for lock each time the CM7
executes the lock command. (Length of output time will be based on feature 1-02 option settings.)
FO4 - Lock and unlock:
This option will provide a double pulse lock output for both lock and
unlock each time the CM7 executes lock or unlock commands. (Length of output time will be based
on feature 1-02 option settings.)
1-05 Rearm Output: Factory Alarm Arm (FAA) output function options
FO1 - After start, after shutdown, after first lock:
This option triggers the FAA after every
successful remote start, every successful remote start shut down, and with every first lock command.
(First lock command is the first arm/lock command sent after the CM7 has been disarmed or
unlocked.)
FO2 - After shut down only and first lock:
This option triggers the FAA after every successful
remote start shut down, and with every first lock command. (First lock command is the first arm/lock
command sent after the CM7 has been disarmed or unlocked.)
FO3 - After Start only:
This option triggers FAA after every successful remote start.
FO4 - After shutdown only:
This option triggers the FAA after every successful remote start shut
down.