SV 10 -
AUX1:
provides a 250mA (-) negative output when AUX is triggered by Firstech 4 button
remote, 2way LCD remote, or Drone, on any POC programmed with this setting.
SV 11 -
AUX2:
provides a 250mA (-) negative output when AUX is triggered by Firstech 4 button
remote, 2way LCD remote, or Drone, on any POC programmed with this setting.
SV 12 -
AUX3:
provides a 250mA (-) negative output when AUX3 is triggered, using a Firstech 2 way
LCD remote (please refer to remote users guide for activation steps), on any POC
programmed with this setting.
(Feature 3-11 must be set to option 2)
SV 13 -
AUX4:
provides a 250mA (-) negative output on any POC programmed with this setting,when
AUX4 is triggered using a Firstech 2 way LCD remote (please refer to remote users guide for
activation steps),
(Feature 3-11 must be set to option 2)
SV 14 -
AUX5:
provides a 250mA (-) negative output on any POC programmed with this setting,
when AUX5 is triggered, using a Firstech 2 way LCD remote (please refer to remote users
guide for activation steps), on any POC programmed with this setting. (Feature 3-11 must be
set to option 2)
SV 15 -
AUX6:
provides a 250mA (-) negative output on any POC programmed with this setting,
when AUX6 is triggered, using a Firstech 2 way LCD remote (please refer to remote users
guide for activation steps), on any POC programmed with this setting. (Feature 3-11 must be
set to option 2)
SV 16 -
AUX7:
provides a 250mA (-) negative output on any POC programmed with this setting,
using a Firstech 2 way LCD remote (please refer to remote users guide for activation steps
(Feature 3-11 must be set to option 2)
SV 17 -
Defrost:
provides a 250mA (-) negative output on any POC programmed with this setting,
when defrost function has been activated (output time based on features 3-13 and 3-14
option settings)
SV 18 -
GWA (ground While Armed):
provides a 250mA (-) negative output on any POC
programmed with this setting, while the system is armed or locked.
SV 19 -
GWR 2 (status output 2):
provides a 250mA (-) negative output on any POC programmed
with this setting, when the remote start sequence is activated and continue until after the
remote start has shut down.
Note: With GWR 2 the output will not provide ground
during reservation mode set up in order to avoid any possible factory immobilizer
issue that may occur if the vehicle sees 2 or more immobilizer override coding.
SV 20 -
Siren 2:
provides a 250mA (-) negative output on any POC programmed with this setting,
only with the full alarm or panic modes. May be used to power any additional horn or sirens
while the CM7 is in full alarm or panic mode.
SV 21 -
Defrost 2:
provides a 250mA (-) negative pulsed output only on any POC programmed with
this setting, when the defrost output is engaged based on the temp setting of feature 3-13.
SV 22 -
VAC (Ventilation and Air Conditioning):
provides a 250mA (-) negative output on any
POC programmed with this setting, when the VAC feature is activated based on temperature
settings of feature 3-12 during the remote start sequence.
setting, (based on timing set for AUX 3)
only when the CM7 is unlocked using the EZGO
proximity unlock feature.
SV 25 -
Lock:
provides a 250mA (-) negative output on any POC programmed with this setting, with
the lock/arm command.
Copyright 2014 Firstech, LLC.
Page 2
Copyright 2014 Firstech, LLC.
Page 2
CM7200
Master Guide
Starter System
techfeed.compustar.com
Copyright 2014 Firstech, LLC.
Page 47
SV 23 -
N/A
SV 24 -
AUX3 EZGO:
provides a 250mA (-) negative output on any POC programmed with this