3-03 Dome Light Delay: This option is used when connecting the door trigger input to the vehicles dome
light circuit. It delays the door trigger input to prevent the door open icon displaying on 2 Way
remotes upon lock/arm.
FO1- Off:
(default)
FO2 - 5 seconds:
This option will delay the door trigger input for 5 seconds when arming the
system to account for any vehicle dome light output delay.
FO3 - 45 seconds:
This option will delay the door trigger input for 45 seconds when arming the
system to account for any vehicle dome light output delay.
FO4 - Auto:
This option will allow the CM7 to wait for a change in polarity on the door input circuit,
after the system has been armed, to monitor for security.
3-04 Starter-Kill: This option determines the operation of the GWA wire (POC 1 CN4 Pin 1 Blue/white)
FO1 - Anti grind + Starter interrupt:
this option will allow for POC 1 to provide a negative
output when the system is armed or remote started. This will enable a starter interrupt to prevent the
vehicle from being started with the key when in an armed state.
FO2 - Anti Grind only:
This option will allow POC 1 to provide a negative output when the system
is armed. This will enable starter interrupt and prevent the user from grinding the starter during the
takeover procedure.
FO3 - Anti Grind and passive starter interrupt:
This option will allow for POC 1 to provide a
negative output when the system is remote started or the passive starter interrupt is engaged. This will
prevent the user from grinding the starter during the takeover procedure and enable starter interrupt
45 seconds after the ignition has been turned off.
3-06 Factory Alarm Option: This feature will enable or disable the security features of the CM7000, or
CM7200. Security features include sensor inputs, zone inputs (unless using with manual transmission),
horn, and siren output. Basic features will function normally (lock, unlock, trunk release, remote start,
parking lights.)
FO1 - Off:
(CM7200 default)/FO1- On: (default CM7000) Depending on the Control Module this
option will enable or disable the security features.
FO2 - On:
(CM7200)/FO2- off (CM7000) Depending on the Control Module this option will enable
or disable the security features.
3-08 Horn output: This feature controls the horn output behavior during Arm, Disarm, and Remote Start.
(POC setting #8)
FO1 - On double lock only:
(default) this option is design to simulate a factory keyless entry
system by providing a horn output pulse (based on the option selection of feature 3-02) each time the
lock command is sent a second time within 8 seconds of the first lock command.
FO2 - On lock and Unlock only:
this option will provide a horn output pulse (based on the
option selection of feature 3-02) with each lock or unlock confirmation.
FO3 - On lock, Unlock, and Start:
this option will provide a horn output pulse (based on the
option selection of feature 3-02) with each lock, unlock, remote start command and remote started
confirmation.
Copyright 2014 Firstech, LLC.
Page 2
Copyright 2014 Firstech, LLC.
Page 2
CM7200
Master Guide
Starter System
techfeed.compustar.com
Copyright 2014 Firstech, LLC.
Page 38