Firesafe 829-0301 Instructions For Use Manual Download Page 12

 

10 

 9.

 

Parts and Spares 

Part Number* 

Description 

Calibration 

Pressure 

   829-0301 

Firesafe™ Flowmeter - O

2

 Single Direct 0 – 15 l/min - BS 5682 connector 

400 kPa 

   829-0302 

Firesafe™ Flowmeter - O

2

 Dual Direct 0 – 15 l/min - BS 5682 connector 

400 kPa 

   829-0303 

Firesafe™ Flowmeter - O

2

 Single Indirect (1.5m) 0 – 15 l/min - BS 5682 connector 

400 kPa 

   829-0304 

Firesafe™ Flowmeter - O

2

 Dual Indirect (1.5m) 0 – 15 l/min - BS 5682 connector 

400 kPa 

   829-0351 

Firesafe™ Flowmeter - Air Single Direct 0 – 15 l/min - BS 5682 connector 

400 kPa 

   829-0352 

Firesafe™ Flowmeter - Air Dual Direct 0 – 15 l/min - BS 5682 connector 

400 kPa 

   829-0353 

Firesafe™ Flowmeter - O

2

 Dual Indirect (3m) 0 – 15 l/min - BS 5682 connector 

400 kPa 

   829-0901 

Firesafe™ Flowmeter - O

2

 Single Direct 0 – 15 l/min - SIS connector (AS 2896) 

400 kPa 

   829-0902 

Firesafe™ Flowmeter - O

2

 Dual Direct 0 – 15 l/min - SIS connector (AS 2896) 

400 kPa 

   829-0951 

Firesafe™ Flowmeter - Air Single Direct 0 – 15 l/min - SIS connector (AS 2896) 

400 kPa 

   829-0952 

Firesafe™ Flowmeter - Air Dual Direct 0 – 15 l/min - SIS connector (AS 2896) 

400 kPa 

   829-1001 

Firesafe™ Flowmeter - O

Single Direct 0 – 15 l/min - BS 5682 connector (New Zealand) 

400 kPa 

   829-1002 

Firesafe™ Flowmeter - O

2

 Dual Direct 0 – 15 l/min - BS 5682 connector (New Zealand) 

400 kPa 

   829-1051 

Firesafe™ Flowmeter - Air Single Direct 0 – 15 l/min - BS 5682 connector (New Zealand) 

400 kPa 

   829-1052 

Firesafe™ Flowmeter - Air Dual Direct 0 – 15 l/min - BS 5682 connector (New Zealand) 

400 kPa 

*All listed part numbers are standard configurations; please contact your BPR Medical distributor for others 

 Spare Parts 

   827-0031 

Firesafe™ Nozzle (10 pack) 9/16” UNF (DISS) Female 

 

 

Summary of Contents for 829-0301

Page 1: ...702 0049 22 September 2020 Firesafe Flowmeter Instructions for Use...

Page 2: ......

Page 3: ...6 4 1 Connecting to Gas Supply 6 4 2 Adjusting the Flow 6 4 3 Reading the Flowmeter 6 4 4 Connecting to Patient 6 4 5 During Use 7 4 6 After Use 7 5 Cleaning and Disinfection 7 5 1 Cleaning 7 5 2 Sus...

Page 4: ...injury if their oxygen supply is not available or is stopped unexpectedly The flowmeter is not MRI compatible Ensure that the medical gas supply is sufficient for the proposed therapy and is supplied...

Page 5: ...sition Failure to do so may result in incorrect flow rates being displayed Arrange the oxygen tubing and gas hose carefully to avoid damage to the hose and the potential for causing a trip hazard Neve...

Page 6: ...vices 3 2 Technical Description The Firesafe enables accurate control of the flow of either medical oxygen or medical air model dependent in the range of 1 to 15 l min A precision rotating float rises...

Page 7: ...fluted rim which continuously rotates in the gas stream to provide visual confirmation that gas is flowing and the device is providing an accurate reading Historically incidents have occurred with co...

Page 8: ...connection before turning on the supply pressure Do not use the device to tighten or lock the connection For quick connector probes e g BS 5682 DIN AFNOR ensure that the connection is correctly made b...

Page 9: ...formed every six months if used infrequently an annual check may suffice 6 1 1 Leak Test Attach the flowmeter to a low pressure medical gas supply with a nominal supply pressure as specified on the ra...

Page 10: ...n flow rates different from the flow settings Supply Pressure Range Minimum 370 kPa Maximum 550 kPa Accuracy Nominal Pressure 10 of indicated reading between 1 15 l min Valve Settling 2 from initial s...

Page 11: ...to operate the medical gas pipeline system isolation valves Inlet filter blocked Repair required Flowsafe Valve has activated Flowsafe Valve is designed to activate when an exceptionally high flow of...

Page 12: ...Flowmeter O2 Single Direct 0 15 l min SIS connector AS 2896 400 kPa 829 0902 Firesafe Flowmeter O2 Dual Direct 0 15 l min SIS connector AS 2896 400 kPa 829 0951 Firesafe Flowmeter Air Single Direct 0...

Page 13: ...er Service Centre 10 Julius Avenue North Ryde Sydney NSW 2113 T 61 0 2 8874 4400 F 61 0 2 9886 9000 www boc com au New Zealand BOC Healthcare Customer Service Centre 970 992 Great South Road Penrose 1...

Page 14: ...12...

Page 15: ...13...

Page 16: ...BPR Medical Limited 44 0 1623 628 281 Qarad EC REP BV 22 Hamilton Way Mansfield Notts info bprmedical com Pas 257 2440 Geel NG18 5BU United Kingdom www bprmedical com Belgium...

Reviews: