30
Finalizing the Installation
(for qualified installers only)
© Travis Industries
4/23/2021 - 1552
564 GSR2 35K CF
Class A Chimney Conversion
Duravent provides a conversion kit for those wishing to use an existing class A chimney to vent this direct
fireplace. The illustration below gives an overview of this type of installation. See the instructions included with
the kit for details.
All requirements in the appliance manual must be met. This includes compliance with vent configuration
charts. Remember to set the restrictor position to the correct position (based upon the vertical rise height -
see the vent charts in the appliance manual.
These conversion kits do not work on interior masonry chimneys.
The measurements below refer to the Chimney Inside Diameter
Chimney Conversion Kit A (46DVA-KCA)
6” DuraTech
6” Security Chimney
6” Metalbestos
6” Jackes-Evans
6” Hart & Cooley
6” Pro-Jet
Chimney Conversion Kit B (46DVA-KCB)
6” DuraPlus
7”-8” DuraTech
8” Security Chimneys
7”-8” Metalbestos
7”-8”Jackes-Evans
7”-8”Hart & Cooley
7”-8”Pro-Jet
6”-7” Amer. Metals
6”-7”Metal-Fab
6” Air-Jet
Chimney Conversion Kit C (46DVA-KCC)
7”-8” DuraPlus
8” American Metals
8” Air-Jet
8” Metal-Fab
Each Kit Contains:
Cap Adapter
Retro Connector
Additional Required Equipment:
4" Flex (#711 or U.L. 1777)
Termination (46DVA-VCH)
Co-Axial Sections