6
Installation
(for qualified installers only)
Travis Industries
9 3 5 0 8 1 0 3
1 5 1 0 0 2
Installation Warnings:
!
Failure to follow all of the requirements may result in property damage, bodily
injury, or even death.
!
This heater must be installed by a qualified installer who has gone through a
training program for the installation of direct vent gas appliances.
!
This appliance must be installed in accordance with all local codes, if any; if not, in
U.S.A. follow ANSI Z223.1 and NFPA 54(88), in Canada follow B-149.
!
In Manufactured or Mobile Homes must confirm with: In USA, Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280; In Canada, CSA Z240.4
and Gas-Equipped Recreational Vehicles and Mobile Housing. This appliance may
be installed in Manufactured Housing only after the home is site located.
!
The 36DV is designed to operate on natural gas, or propane (LP).
All exhaust gases must be vented outside the structure of the living-area.
Combustion air is drawn from outside the living-area structure.
!
Notify your insurance company before hooking up this fireplace.
!
The requirements listed below are divided into sections. All requirements must be
met simultaneously. The order of installation is not rigid Ð the qualified installer
should follow the procedure best suited for the installation.
Packing List
¥
Propane Conversion Kit
¥
Log Set (Log Set, Coals, & Glowing Embers)
¥
Electrical Connector (3 wires - female molex)
¥
Flex Tube with Pipe Adapter
¥
Glass Latch Tool (to un-latch glass frame)
¥
Arch Covers (for arched faces only)
Additional Items Required
¥
Faceplate (gold or black) - Includes attachment screws
¥
Direct Vent (Simpson Dura-Vent Ph. # 800 835-4429)
¥
Gas Line Equipment (shutoff valve, pipe, etc.)
¥
Electrical Equipment (min. 18 gauge, grounded line)
Installation Overview
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AA
AA
AA
AA
AA
AA
AA
AA
Non-combustible facing
(see the section "Facing
Requirements")
See the
section
"Acceptable
Vent Lengths"
See the section
"Horizontal Termination
Requirements"
See the section
"Gas Line Installation"
See the section
"Electrical
Connection"
See the section
"Mantel Requirements"
Insulation must not fill
the spaces between
the stand-offs
See the section "Fireplace
Placement Requirements"
4-1/2" Min.
See the section
"Vent Requirements"
See the section "Minimum
Framing Dimensions"
See the section
"Hearth Requirements"
Drywall
Nail
Down
Plate
See "Power Heat
Vent" in the optional
equipment section.