Installation
(for qualified installers only)
1 1
Travis Industries
9 3 5 0 8 1 0 3
1 5 1 0 0 2
Facing Detail
3-3/4"
35-1/4"
26-3/4"
AA
AA
6-3/4"
21-1/2"
23"
1"
1"
Make sure these shaded areas are faced over
when using the arched face. Rectangular faces
do not require this area to be faced.
AAA
AAA
Access Door
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
1"
Face
1"
1-3/8Ó Rectangular Faces
1/4" Arch Faces
Glass
1/2"
Air Space
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
The overlap is 1-1/2" along
the top of the face.
NOTE:
Do not tuck tile underneath the face on the bottom (there
will be a 1/2" air space below the access door). You may
do this on the sides and top, but not on the bottom.
¥
To achieve a facing that is flush with the drywall to the side of the fireplace, recess the framing directly
next to the fireplace. See the illustration below.
Fireplace
1"
1/2" Drywall
AAA
AAAA
1/2" Concrete Board
3/8" Tile
This 2x4 is recessed 3/8"
to make a flush facing
Fireplace
1/2" Drywall
AAA
AAA
AAA
AAA
1/2" Concrete Board
3/8" Tile
The tile overlaps the drywall
for an overlap facing
Faceplate
1"
TOP
VIEW
Faceplate