Finalizing the Installation
Travis Industries
9 3 5 0 8 1 0 3
1 5 1 0 0 2
!
We recommend you purge the gas line at this time (with the glass removed). This allows gas to be
detected once it enters the firebox, ensuring gas does not build up.
3
Replace the glass (and arch covers when using arched faces - see page 26).
4
Install the faceplate.
!
ACID WASH WARNING
:
Before installing the faceplate, make sure any masonry that has been
treated with acid wash has been properly neutralized (this is used primarily with brick faces). Acid wash
(muriatic acid) is used to remove excess mortar. If not properly neutralized with an ammonia solution,
the gold face may develop a permanent tarnish when the acid evaporates over time. Contact your
dealer if uncertain your facing has been properly neutralized.
Rectangular Faces
Adjust he arch cover
(see page 12). Use the
outside attachments on
the side. There is no
center attachment for
rectangular faces.
Arch Faces
Use the inside
attachments on the
side and the
attachment at the
center of the face.
Phillips
Screwdriver
5
Turn on the gas to the fireplace. Turn on gas to the heater. Leak test all gas joints prior to starting the
appliance. Start the pilot. Start the main burner. Leak test all gas joints again.
6
Check the pilot flame to make sure it looks like the illustration below. Adjust the pilot flame if
necessary.
PILOT ADJ
T
O
L
PI
ON
OFF
Standard
Screwdriver
Micro (1/16Ó)
Standard
Screwdriver
A
Cover Screw
Cover Screw Gasket
Needle Valve
Thermopile
Pilot Hood
3/8Ó
Thermocouple
The pilot flame should touch
only the top 3/8Ó of the
thermopile. Adjust the pilot up
or down as necessary.
To adjust the pilot flame, remove the cover screw and gasket and turn the needle
valve (NOTE: if the needle valve is totally unscrewed, gas will come out of this port).
Clockwise lowers the flame while counter-clockwise raises it. Replace the cover
screw and gasket