10/01/2021 Rev. 02
8
Reference Figure 1 for the following page.
Fire Button
When in manual show mode, the fire button will fire the next channel on the selected module.
When in SMPTE mode or Internal clock, the FIRE button will begin firing the uploaded script.
Battery Charging Ind Battery Power Indicator
Charge LEDs indicate the power status of the CM. The red LED indicates the battery is
charging. The green LED indicates the battery is fully charged.
Navigation Buttons
The navigation buttons are used to navigate between menus on the CM.
Control Buttons
The control buttons are used to select which screen the CM will display. The CM may display
the HOME, MENU, CONTINUITY TESTING (CT), WIRELESS WIZARD (WW), MODULE
STATUS (MOD), or SHOW screen. The ARM/SAFE button is used with the ARM key to
arm/disarm the system.
Timing Controls
The timing controls are used to pause and stop the internal clock show. With future updates,
these controls will control the Audio Module, to reverse, pause, play, stop, or forward the
show.
Open Pyro Network (OPN) Button
The Open Pyro Network (OPN) button opens the OPN CONFIGURATION menu. This menu
is used to configure whichever OPN module is installed, whether that be an Ethernet card
or a 32-shot expansion card.
10-Key Number Pad (Numpad)
The 10-key number pad (Numpad) is used to view, navigate, and select menus and
modules. To select a module, enter the module ID number on the Numpad. Some numbers,
like the module ID, show as “001;” these leading zeros do not need to be entered to select
that module.