10/01/2021 Rev. 02
33
6.
Continuity
-
CAUTION
– You cannot ARM while in Continuity Test (CT) Mode and
you cannot run CT while Armed. They are mutually exclusive for safety reasons.
Please be advised that the FM screen will display the results from the last continuity
check when CT Mode is NOT active on the CM. For live CT results you must have
CT Mode enabled on the CM. While CT mode is enabled, you will be able to view live
results on the FM or the CM. This will ensure that you are viewing live data
.
From the CM, enable continuity testing. Press the CT button on the FM to view
individual continuity results. See Section 2: Basic Setup; #5 Perform Continuity Test
for additional information.
Please note that Continuity Test Mode will only run with e-matches. The LEDs Test
Lights do not pass continuity, as the LED acts as a diode (instead of a short-circuit
like an e-match) and will not allow enough current through it to show continuity is
viable.