10/01/2021 Rev. 02
28
2Wire Input/Output
(Figure 31)
The three 2Wire ports are used for 2Wire communications between the CM and all FMs.
The color of each terminal is not important. The polarity of the two wires (when plugged into
the next unit) is not important. Connections can be made in “daisy-chain order” (one cable
in, one cable out) or “star order” (one cable in, two cables out) or any other order in the
network. For ease of debugging, use the single input terminal set on the FM (near the top)
for the input, and one or both terminal sets (near the bottom) as outputs.
Only one
connection can be made per set of 2Wire terminals.
Section 2: Basic Setup
1.
Turn on FM(s)
- Press and hold the power button until internal lights turn on,
approximate 3 to 5 seconds. A logo splash screen will appear before the Home
screen.
2.
Name all FMs
– Each FM must have a unique ID number before joining a CM. On
each FM press MENU, the NAME option on the menu will be pre-selected, press
ENTER. Use the left (
←
), up (
↑
), right (
→
), and down (
↓
) arrow keys to choose a unique
ID. Press ENTER to set ID – valid ID numbers are 001 to 999.
3.
Join FMs to CM
– On the CM, press MENU-> (3): JOIN, ENTER. On the FMs, press
MENU and use the arrow keys to select JOIN MODE. Press ENTER. If the screens
match, on both the CM and FMs, press YES on the FMs first – then press HOME.
Press HOME on the CM when all FMs have been joined. If the numbers do not match,
press NO on the FMs. The FM will then display the ID number of the next CM detected
in the area. Continue until both numbers are the same, then press HOME on the CM.
Figure 31