6.
Arm system –
NOTICE
– You cannot Arm while in Continuity Test and you cannot
run CT while Armed. To arm the system, turn the ARM key clockwise to the ARM
position, then press the ARM/SAFE button. FMs will blink yellow and red for three
seconds as the capacitor bank charges. Once the capacitor bank is fully charged,
the FMs will turn RED and the CM will automatically transition to the SHOW page.
7.
Fire show
– Either a Manual, SMPTE, or Internal Clock show may be fired from the
SHOW page (see figure 10). Use the left (
←
) and right (
→
) arrow keys to navigate
between these pages (this may be done even while a show is running).
•
Manual –
From the MANUAL FIRING page, use the up (
↑
) and down (
↓
) arrow
keys to scroll through FMs in numerical order. Use the Numpad to select any FM.
Use the channel selection buttons to select which shot to fire. Use the FIRE button
to fire each shot. With each press of the FIRE button, the system will automatically
advance to the next shot and, when appropriate, to the next FM. (figure 11)
Figure 10