background image

7

CLEARANCES FOR VENTED APPLICATIONS

PROPER CLEARANCES FROM COMBUSTIBLE
CONSTRUCTION AND MATERIALS MUST BE
MAINTAINED FROM ALL SIDES, TOP, AND BOTTOM
OF THIS APPLIANCE.

THIS APPLIANCE SHOULD NEVER BE PLACED
NEAR ANY COMBUSTIBLE SURFACE.

THIS APPLIANCE SHOULD NEVER BE PLACED
UNDER ANY COMBUSTIBLE CONSTRUCTION OR
MATERIALS.

NEVER PLACE ANY COMBUSTIBLE MATERIAL
WITHIN TWENTY-FOUR ( 24” ) FROM THE FRONT
OF THE FIREPLACE ENCLOSURE.

FIGURE 9

!!! WARNING !!!

FOR VENTED APPLICATIONS: The damper clamp must be
installed in a manner, which will maintain the minimum
permanent damper vent opening at all times. SEE FIGURE 9.
See the Decorative Gas Log Set Specifications on page 3 & 4.

!!! WARNING !!!

The State of Massachusetts requires that the chimney flue
damper, when used with decorative gas log sets, be welded
open or completely removed. In the Commonwealth of
Massachusetts, this appliance must be installed by a licensed
plumber or gasfitter.

!!! WARNING !!!

FOR VENTED APPLICATIONS: This appliance, must be
installed only in a solid-fuel burning fireplace with a working
flue and constructed of noncombustible materials. This unit is
NOT for use with solid fuel. Solid fuels shall NOT be burned in
a fireplace where a decorative gas appliance is installed.

INSTALLATION

Installation will be much easier if two ( 2 ) or more people co-
operate in locating and installing the unit.

LOCATION

FOR VENTED APPLICATONS: This appliance must be
installed only in a solid-fuel burning fireplace, with a working
flue, and constructed of noncombustible materials.

!!! WARNING !!!

Gas supply system must be installed in accordance with the
U.S. National Fuel Gas Code.

This appliance and its individual shut off valve must be
disconnected from the gas supply piping system during any
system pressure test in excess of ½ PSI ( 3.5 KPA ).

Use a system manual shut off valve to shut off the gas supply
to this gas appliance before continuing with installation
procedures.

!!! IMPORTANT !!!

FOR VENT-FREE APPLICATIONS: If the appliance is to be
installed in a solid-fuel burning fireplace, have the fireplace and
chimney, professionally cleaned, to remove any ashes, soot,
creosote, or loose debris. The fire box must be sealed from
any potential drafts, from cleanouts, ill-fitting dampers, cracks,
etc…

!!! IMPORTANT !!!

FOR VENT-FREE APPLICATIONS: Seal any fresh air vents or
ash clean-out doors located on the floor or wall of the fireplace.
If this is not performed, drafting may cause pilot outage or
sooting. Use a heat-resistant sealant. SEAL THE DAMPER,
ONLY IN VENT-FREE APPLICATIONS!

!!! IMPORTANT !!!

FOR VENTED APPLICATIONS: Before installing this
appliance, have the fireplace and chimney, professionally
cleaned, to remove any ashes, soot, creosote, or other
obstructions. Perform this cleaning annually, after installation.

!!! IMPORTANT !!!

FOR VENTED APPLICATIONS: Seal any fresh air vents or
ash clean-out doors located on the floor or wall of the fireplace.
If the above conditions are not met, drafting may cause pilot
outage or sooting. Use a heat-resistant sealant; DO NOT seal
the chimney flue damper.

!!! IMPORTANT !!!

Decorative Gas Log Sets are shipped with the appropriate gas
connections for each type of gas, i.e., Natural Gas or Liquid
Propane. If you have purchased an inappropriate unit for your
application, contact your retailer, installer, or the firegear
Customer Service Center.

WARNING

: This appliance is equipped for ( Natural or

Propane ) gas. Field conversion is not permitted.

Summary of Contents for AF-1100 VALVE SERIES

Page 1: ...information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life This is an un vented gas fired heater It uses air Oxygen from...

Page 2: ...and the products of combustion of such fuels contain chemicals known to the State of California to cause cancer birth defects and or other reproductive harm This warning is issued pursuant to Californ...

Page 3: ...rvice agency or the gas supplier WARNING When used without adequate combustion and ventilation air heater may give off excessive CARBON MONOXIDE an odorless poisonous gas WARNING Before you install th...

Page 4: ...insure safe installation Failure to follow these instructions exactly can create a fire hazard SIDEWALL CEILING CLEARANCES FIGURE 2 The sides of the fireplace opening must be a minimum of six 6 inche...

Page 5: ...he mantel FLOOR CLEARANCES If installing the appliance at floor level the minimum clearance to combustible material is six 6 inches SEE FIGURE 5 FIGURE 5 EXAMPLE OF COMBUSTIBLE MATERIAL DO NOT attach...

Page 6: ...ted room heater having an input rating of more than 6 000 Btu per hour shall not be installed in a bathroom INSTALLATION INFORMATION UNVENTED APPLICATIONS WARNING This appliance is for installation on...

Page 7: ...tional Fuel Gas Code This appliance and its individual shut off valve must be disconnected from the gas supply piping system during any system pressure test in excess of PSI 3 5 KPA Use a system manua...

Page 8: ...for the gas connection with the exception of ember material and log placement IMPORTANT BEFORE YOU BEGIN Audit the gas pressure at the fireplace stub to insure proper minimum gas pressure see the spe...

Page 9: ...sooting SEE FIGURE 12 NOTE Special care is required if you are installing the appliance into a sunken fireplace The fireplace floor must be raised using non combustible materials to allow access to th...

Page 10: ...will be necessary for your distance run 1 Using a Jeweler s Phillips screwdriver install the stripped ends of connecting wire into the screw terminal block on the rear of the remote receiver FOR HAND...

Page 11: ...HAND HELD TRANSMITTER REMOTE RECEIVERS USE THE OUTSIDE TERMINAL BLOCK RECEPTACLES SEE FIGURE 16 17 WALL MOUNT REMOTE RECEIVER See the instructions packaged with the remote system for directions on pr...

Page 12: ...eeded to cover the area and the use of too much will retard the yellow flame and eliminate the glow Apply just enough to obtain a slow glow DO NOT PLACE GLOWING EMBERS DIRECTLY ON THE BURNER PORTS THI...

Page 13: ...ctive wrapping from the gas logs 5 Arrange the decorative gas logs on the burner base according to the instructions packaged with the gas logs 6 Place the Lava Rock cinders around the Grate Burner ass...

Page 14: ...the gas valve control knob Pilots may also be lit by long hearth match hand fire starter or book match clip extender All units must be lit by a Safety Pilot Pilot is located at the rear left center of...

Page 15: ...ty information in this manual LIGHTING THE PILOT 2 Push in the gas control knob slightly and turn it in a clockwise direction to the OFF position DO NOT FORCE NEVER USE ANY TOOL TO ROTATE THE GAS CONT...

Page 16: ...tructions given for curing the logs to avoid cracking the logs with continued use After the initial lighting of the burner system adjust the flame to about two 2 inches Allow the flame to burn for thi...

Page 17: ...420 NG OR S 37 5 37 BRASS ORIFICE STEM TYPE 20 THREAD HEX 360 NG PI 1 14 PIEZO IGNITER PIW 18 15 PIEZO IGNITER WIRE 18 REG 35 9 REGULATOR 3 5 W C NG REV EMB A COMMON PARTS PAGE REVOLUTION EMBERS ROCK...

Page 18: ...S 52 5 52 BRASS ORIFICE STEM TYPE 20 THREAD HEX 420 LP OR S 53 5 53 BRASS ORIFICE STEM TYPE 20 THREAD HEX 360 LP PI 1 17 PIEZO IGNITER PIW 18 18 PIEZO IGNITER WIRE 18 REG 10 11 REGULATOR 10 0 W C LP...

Page 19: ...and descriptions When ordering parts first obtain the Model Number from the name plate on your equipment then determine the PART NUMBER not the Index Number and the part description of each part from...

Page 20: ...HELD ON OFF REMOTE FG LT TH2 HAND HELD ON OFF THERMOSTAT REMOTE FG LMF SM1 or 2 HAND HELD ON OFF HI MED LOW FLAME REMOTE FIREGEAR WALL MOUNT REMOTE SYSTEMS FG WS LT WIRED WALL SWITCH FG WWS LT WIRELE...

Page 21: ...Check gas supply pressure while pilot remains on Faulty Valve Replace Valve Faulty pilot or thermocouple Replace Safety Pilot Clogged or dirty burner ports Clean burner ports Faulty Regulator Replace...

Page 22: ...ited Warranty does not cover any failures or operating difficulties due to accident abuse misuse alteration misapplication vandalism improper installation or improper maintenance or service or failure...