5
MANTEL CLEARANCES WITHOUT HOOD continued
MANTEL WITHOUT HOOD
FIGURE 3
MANTEL CLEARANCES WITH HOOD
FIGURE 4
A mantel may project from the wall a maximum of two ( 2” )
inches, at a minimum of thirteen and one-half ( 13 ½” ) inches,
above the fireplace opening, and a maximum of six ( 6” )
inches, at a minimum of fifteen ( 15” ) inches, above the
fireplace opening. ( SEE FIGURE 4 )
!!! WARNING !!!
If your installation does NOT meet the minimum clearances,
you MUST:
1-
Operate this appliance with the chimney flue damper
open; or
2-
Raise the mantel to the proper height; or
3-
Remove the mantel.
FLOOR CLEARANCES
If installing the appliance at floor level, the minimum clearance
to combustible material is six ( 6” ) inches. ( SEE FIGURE 5 )
FIGURE 5
EXAMPLE OF COMBUSTIBLE MATERIAL
DO NOT
attach any combustible materials to the mantel of
your fireplace. This is a FIRE HAZARD! ( SEE FIGURE 6 )
FIGURE 6
DO NOT
attach greeting cards, stockings, or any type of
ornamentation to the mantel or fireplace. This is a heating
appliance; the flow of heat can ignite combustible material.
( SEE FIGURE 7 )
FIGURE 7
HEAT RESISTANT
MATERIAL 12” WITHOUT
HOOD
HEATER IN FIREPLACE
OR FIREBOX
28”
12”
HEAT RESISTANT
MATERIAL 8” WITH
HOOD
HEATER IN
FIREPLACE
OR FIREBOX
HOOD
8” Mantel
6” Mantel
4” Mantel
2” Mantel
14.25”
13.5”
15”
16”
6”
COMBUSTIBLE
MATERIAL
HEATER IN
FIREPLACE
Summary of Contents for AF-1100 VALVE SERIES