FIREGEAR REVOLUTION VENTED / UNVENTED GAS LOG

HEARTH KIT TROUBLE SHOOTING

PROBLEM OBSERVED

POSSIBLE CAUSE

CORRECTIVE MEASURE

Gas odor during set up

Gas leak

See " What to do if you smell gas " page 1
Check all gas connections

Gas odor before first ignition

Gas leak

See " What to do if you smell gas " page 1
Check all gas connections

Pilot will not ignite, or will not stay lit

No gas to pilot

Make sure gas is on, in pilot position

Thermocouple not hot

Depress valve knob for at least 1 minute

Improper pilot flame adjustment

See Pilot Characteristics - adjust flame

Loose connections on thermocouple

Check gas connections

Faulty pilot or thermocouple

Replace Safety Pilot

Faulty Regulator

Replace Regulator

Faulty Valve

Replace Valve

Delayed ignition

Low gas pressure

Check gas supply pressure

Clogged or dirty burner ports

Clean burner ports

Blocked orifice

Check orifice opening

Faulty Valve

Replace Valve

Faulty Regulator

Replace Regulator

Burner does not light but pilot remains on

Low gas pressure

Check gas supply pressure

Clogged or dirty burner ports

Clean burner ports

Blocked orifice

Check orifice opening

Faulty pilot or thermocouple

Replace Safety Pilot

Faulty Valve

Replace Valve

Faulty Regulator

Replace Regulator

Burner lights but does not stay lit

Low gas pressure

Check gas supply pressure

while pilot remains on

Faulty Valve

Replace Valve

Faulty pilot or thermocouple

Replace Safety Pilot

Clogged or dirty burner ports

Clean burner ports

Faulty Regulator

Replace Regulator

Burner & pilot light but will not stay on

Low gas pressure

Check gas supply pressure

Not enough fresh air for ODS

Open door or window - ventilate

Faulty Valve

Replace Valve

Faulty pilot or thermocouple

Replace Safety Pilot

Clogged or dirty burner ports

Clean burner ports

Faulty Regulator

Replace Regulator

Remote control overheating

Move away from flame

Remote control batteries failing

Replace batteries

Incorrect burner flame

Incorrect gas supply or pressure

Check gas supply pressure

Blocked orifice

Check orifice opening

Clogged or dirty burner ports

Clean burner ports

Faulty Valve

Replace Valve

Faulty Regulator

Replace Regulator

High altitude

Adjust orifice size for altitude

Backfire of burner

Blocked orifice

Check orifice opening

Clogged or dirty burner ports

Clean burner ports

Low gas pressure

Check gas supply pressure

Appliance produces unwanted odors

Vapors from paint, hair spray, glues, etc

Ventilate room

Initial burn off of manufacturing chemicals

Ventilate room

Logs appear to smoke

Vapors from manufacturing chemicals

Ventilate room

Logs curing

See curing of Refractory Logs

Whistle noise from appliance

Air in gas line

Bleed lines

Control knob not in fully open position

Open control knob to full open

Spiral gas flex line

Replace gas feed line

Summary of Contents for AF-1100 VALVE SERIES

Page 1: ...information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life This is an un vented gas fired heater It uses air Oxygen from...

Page 2: ...and the products of combustion of such fuels contain chemicals known to the State of California to cause cancer birth defects and or other reproductive harm This warning is issued pursuant to Californ...

Page 3: ...rvice agency or the gas supplier WARNING When used without adequate combustion and ventilation air heater may give off excessive CARBON MONOXIDE an odorless poisonous gas WARNING Before you install th...

Page 4: ...insure safe installation Failure to follow these instructions exactly can create a fire hazard SIDEWALL CEILING CLEARANCES FIGURE 2 The sides of the fireplace opening must be a minimum of six 6 inche...

Page 5: ...he mantel FLOOR CLEARANCES If installing the appliance at floor level the minimum clearance to combustible material is six 6 inches SEE FIGURE 5 FIGURE 5 EXAMPLE OF COMBUSTIBLE MATERIAL DO NOT attach...

Page 6: ...ted room heater having an input rating of more than 6 000 Btu per hour shall not be installed in a bathroom INSTALLATION INFORMATION UNVENTED APPLICATIONS WARNING This appliance is for installation on...

Page 7: ...tional Fuel Gas Code This appliance and its individual shut off valve must be disconnected from the gas supply piping system during any system pressure test in excess of PSI 3 5 KPA Use a system manua...

Page 8: ...for the gas connection with the exception of ember material and log placement IMPORTANT BEFORE YOU BEGIN Audit the gas pressure at the fireplace stub to insure proper minimum gas pressure see the spe...

Page 9: ...sooting SEE FIGURE 12 NOTE Special care is required if you are installing the appliance into a sunken fireplace The fireplace floor must be raised using non combustible materials to allow access to th...

Page 10: ...will be necessary for your distance run 1 Using a Jeweler s Phillips screwdriver install the stripped ends of connecting wire into the screw terminal block on the rear of the remote receiver FOR HAND...

Page 11: ...HAND HELD TRANSMITTER REMOTE RECEIVERS USE THE OUTSIDE TERMINAL BLOCK RECEPTACLES SEE FIGURE 16 17 WALL MOUNT REMOTE RECEIVER See the instructions packaged with the remote system for directions on pr...

Page 12: ...eeded to cover the area and the use of too much will retard the yellow flame and eliminate the glow Apply just enough to obtain a slow glow DO NOT PLACE GLOWING EMBERS DIRECTLY ON THE BURNER PORTS THI...

Page 13: ...ctive wrapping from the gas logs 5 Arrange the decorative gas logs on the burner base according to the instructions packaged with the gas logs 6 Place the Lava Rock cinders around the Grate Burner ass...

Page 14: ...the gas valve control knob Pilots may also be lit by long hearth match hand fire starter or book match clip extender All units must be lit by a Safety Pilot Pilot is located at the rear left center of...

Page 15: ...ty information in this manual LIGHTING THE PILOT 2 Push in the gas control knob slightly and turn it in a clockwise direction to the OFF position DO NOT FORCE NEVER USE ANY TOOL TO ROTATE THE GAS CONT...

Page 16: ...tructions given for curing the logs to avoid cracking the logs with continued use After the initial lighting of the burner system adjust the flame to about two 2 inches Allow the flame to burn for thi...

Page 17: ...420 NG OR S 37 5 37 BRASS ORIFICE STEM TYPE 20 THREAD HEX 360 NG PI 1 14 PIEZO IGNITER PIW 18 15 PIEZO IGNITER WIRE 18 REG 35 9 REGULATOR 3 5 W C NG REV EMB A COMMON PARTS PAGE REVOLUTION EMBERS ROCK...

Page 18: ...S 52 5 52 BRASS ORIFICE STEM TYPE 20 THREAD HEX 420 LP OR S 53 5 53 BRASS ORIFICE STEM TYPE 20 THREAD HEX 360 LP PI 1 17 PIEZO IGNITER PIW 18 18 PIEZO IGNITER WIRE 18 REG 10 11 REGULATOR 10 0 W C LP...

Page 19: ...and descriptions When ordering parts first obtain the Model Number from the name plate on your equipment then determine the PART NUMBER not the Index Number and the part description of each part from...

Page 20: ...HELD ON OFF REMOTE FG LT TH2 HAND HELD ON OFF THERMOSTAT REMOTE FG LMF SM1 or 2 HAND HELD ON OFF HI MED LOW FLAME REMOTE FIREGEAR WALL MOUNT REMOTE SYSTEMS FG WS LT WIRED WALL SWITCH FG WWS LT WIRELE...

Page 21: ...Check gas supply pressure while pilot remains on Faulty Valve Replace Valve Faulty pilot or thermocouple Replace Safety Pilot Clogged or dirty burner ports Clean burner ports Faulty Regulator Replace...

Page 22: ...ited Warranty does not cover any failures or operating difficulties due to accident abuse misuse alteration misapplication vandalism improper installation or improper maintenance or service or failure...

Page 23: ...23 NOTES...

Page 24: ...24 www firegearusa com REVA11 3 4...

Reviews: