Operating instructions FS-26E
Status as of 10 / 2019
Page 42
6.1 Setting values via keypad
Parameter Delivery
state
Vibratory conveyor, level 0
Vibration amplitude
0A
1...230 V~
30 V~
Min. control limit
0A>
1...230 V~
30 V~
Max. control limit
0A<
1...230 V~
230 V~
Current limit
0St
0.1...6 A~
6 A~
Vibration frequency
0F
5.0...200Hz
50.0 Hz
Soft start ramp
0SA 0.1...5 seconds
0.5 second
Soft stop ramp
0SS 0.1...5 seconds
0.5 second
Nominal value selection
0AE F - Keypad
P - External potentiometer
U - Voltage 0 .. 10 V DC
I - Current 4 .. 20 mA
b - Acceleration sensor
F
Wave form
0FO ^^^^^ (G) full-wave or
^ ^ ^ (H) half-wave
G
Lower acceleration limit
0t>
0.0 - 20.0
0.0
Upper acceleration limit
0t<
0.0 - 20.0
20.0
Proportional factor, control
0rP
0.1 - 19.9
5.0
Working mode
0d
0 - Off
1 - Continuous operation
E - Control
S
Backups
0old 0 - Work parameters
br - Read backup
bs - Save backup
re - Factory settings
0
Nominal control value for
acceleration sensor
0t
0.0 - 20.0
0.0
The max. control limit automatically adapts itself to the active output
voltage range and is then also saved. When changing to the high
range, the limit must be adjusted upward manually. (Safety)