Operating instructions FS-26E
Status as of 10 / 2019
Page 19
4.4 LEVEL d - Information output (display only)
After power ON, the display switches to the "Amplitude" root display. From here, the 6 key can be used
to change to level d. The following values and status displays are available:
Value: Mains voltage [V~]
The currently applied mains voltage is displayed.
Value: Output current [A~]
The currently flowing magnet current is displayed.
Status display: Inputs E1 - E6, depending on availability.
The
upper
row
of
line
segments
shows the physical status, i.e. a line segment
is displayed when voltage is applied to the corresponding input.
E.g.: 24 V DC at E2 = line segment, upper row, pos. 2 from the left
The
lower
row
of
line
segments
shows the logical status, i.e. the status after
processing
inversion
and
times.
E.g.: 0 V at E1 + F1=S = line segment, bottom row, pos. 1 from the left
Status display: Outputs A0 - A7, depending on availability.
The
upper
row
of
line
segments
shows the physical status, i.e. if voltage
is applied to the corresponding output, a line segment is displayed.
E.g.: 24 V DC at A1 = line segment, upper row, pos. 2 from the left
The
lower
row
of
line
segments
shows the logical status, i.e. according to the
logical input and output links and after processing of
inversion and times.
E.g.: 24 V DC at A2 + F2=S = line segment, bottom row, pos. 3 from the left
Status display: Inputs and outputs, depending on availability.
The
upper
row
of
line
segments shows the physical status of the inputs,
i.e.
if
voltage
is
applied
at
the
corresponding input, a line segment is displayed.
The
lower
row
of
line
segments
shows the physical status of the outputs,
i.e.
if
there
is
voltage
applied
at the corresponding output, a line segment is
displayed.
Value: Temperature [°C]
The temperature on the power output stage is output.
Values
up
to
110
are
permissible.