Chapter 4: Diagnostics and Troubleshooting
4-3
Diagnostic Errors
This section contains a Diagnostic Error Code List to help you
quickly identify error codes and Diagnostic Error Descriptions to
provide additional information on the error.
The amber Warning Beacon on top of the inspection head signals
an alarm or error condition by blinking rapidly. To view the Error
Code:
1.
Press the Key 6 to view the Error Code in the LCD.
2.
Press the Arrow Key to scroll through the error description and
to clear the error condition. When you clear the error, the
message resets to zero.
Diagnostic Error Codes Listing
The following list contains the FT-70/75 error codes. Depending
upon your machine type, some of these errors may not apply to
your FT-70/75. For more information see “Diagnostic Error Codes
Descriptions” on page 4-6.
0
No Diagnostic Error
* 2
Rejector Status Is Off
5
Consecutive Reject Queue Error
6
Consecutive Reject Timing Error-Missed Encoder Pulse
10
Fill Level Detection Error-Exceeded Consecutive Reject Limit
11
Missing Cap Detection Error-Exceeded Consecutive Reject Limit
12
High Cap Detection Error-Exceeded Consecutive Reject Limit
13
X-ray Counts Below Reject Threshold Error
14
X-ray Detector Error
15
Missing Cap Sensor Error
16
Trigger Beam Error
17
Encoder Sensor Error
18
Slat Rejector Backup Sensor Is Blocked
19
More than 32 containers between trigger beam and label sensor.
20
Consecutive label timing error with encoder: encoder pulse missed.
22
Encoder Pulse Missed
23
Extra Encoder Pulse Detected
Industrial Dynamics Company, Ltd. Document 40274-0600