9.4
SPECIFIC PROCEDURES
www.maxcessintl.com
DSE-45
MI 2-315 1 A
Configure the DSE-45
Reference:
Configuration Menu Structure, page 8.8.
1.
From an operator interface, select the desired DSE-45.
2.
From the DSE-45 Home Screen, press the ENTER key to enter
the sensor menus.
3.
Select "Configuration", and then press the ENTER key.
4.
Select "Distributed System", and then press the ENTER key.
5.
Select "Application ID", and then press the ENTER key.
6.
Use the arrow keys to set the Application ID number (1 thru
31) (0 disables Application Filtering), and then press the
ENTER key to store the change. (If other Devices in the
network have Application ID numbers assigned, the
application will dictate if the Application ID number in this
DSE-45 should match, or not match, the number in the other
Devices).
7.
Select "Sub Function", then press the ENTER key.
8.
Use the arrow keys to set the Sub Function number (0 thru 4),
and then press the ENTER key to store the change.
9.
Press the ESC key until the DSE-45 home screen is reached.
10.
Repeat this procedure on other sensors, as desired.