Calibration contains a means to calibrate the sensor to the material
being guided. (This calibration is independent from Sensor Calibration
in the Fife Controller/Processor). The DSE-45 is factory-calibrated to
an acoustically opaque material. Generally, it is not necessary to
recalibrate the sensor. If the material to be guided is not acoustically
opaque, it may be possible to improve the performance of the sensor
by performing this calibration.
To calibrate
Click the button, and then follow the on-screen instructions. After
calibration is complete, the total number of transducers present, and
their respective statistics, is displayed. (The statistics are for
evaluation purposes only and do not reflect the overall performance of
the sensor).
To restore the factory calibration values, click on the "Restore Factory
Calibration" button.