3.4
INSTALLATION
www.maxcessintl.com
DSE-45
MI 2-315 1 A
DSE-45 connections
Disconnect power from the DSE-45 before connecting or
disconnecting any cables.
All cable connectors must be tightened sufficiently to provide
the required connection for the cable shielding.
X1 –
ETHERNET
X2 –
AUXILIARY
Auxiliary power (+10.5 to +51 VDC)
Analog output (web width)
X3 –
OUTPUT
-
Connection to controller (default)
-
Power input (+10.5 to +28 VDC)
-
Analog outputs (edge1, edge2, web width)
-
RS-485
Figure 3. DSE-45 connections
Power connection
Power to the DSE-45 should be supplied to either the X2 or X3
Connector, but not to both connectors.
-
When used as a ‘stand-alone’ sensor, power should be
applied to the X2 Connector. Follow the voltage
guidelines in Figure 3.
-
When used as part of a Fife system, the Controller/
Processor generally supplies power to the X3 connector.
If alternate power is to be supplied, refer to the system
drawings for information on power supply requirements.
Verify that the supply is within the above listed limits.