22
ADVAnCED PARAMETERS
51. First channel - minimal time between power reports
This parameter determines minimum time that has to elapse before
sending new power report to the main controller.
Available settings:
0
- reports are disabled
1-120
(1-120s) - report interval
Default setting:
10
(10s)
Parameter size:
1
[byte]
53. First channel - energy reports
This parameter determines the minimum change in consumed ener-
gy that will result in sending new energy report to the main controller.
Available settings:
0
- reports are disabled
1-32000
(1-32000Wh) - change in energy
Default setting:
100
(100Wh) Parameter size:
2
[bytes]
54. Second channel - power reports (FGS-223 only)
This parameter determines the minimum change in consumed power
that will result in sending new power report to the main controller.
Available settings:
0
- reports are disabled
1-100
(1-100%) - change in power
Default setting:
20
(20%)
Parameter size:
1
[byte]
55. Second channel - minimal time between power reports
(FGS-223 only)
This parameter determines minimum time that has to elapse before
sending new power report to the main controller.
Available settings:
0
- periodic reports are disabled
1-120
(1-120s) - report interval
Default setting:
10
(10s)
Parameter size:
1
[byte]
57. Second channel - energy reports (FGS-223 only)
This parameter determines the minimum change in consumed ener-
gy that will result in sending new energy report to the main controller.
Available settings:
0
- reports are disabled
1-32000
(1-32000Wh) - change in energy
Default setting:
100
(100Wh) Parameter size:
2
[bytes]
58. Periodic power reports
This parameter determines in what time interval the periodic power
reports are sent to the main controller.
Available settings:
0
- periodic reports are disabled
1-32000
(1-32000s) - report interval
Default setting:
3600
(1h)
Parameter size:
2
[bytes]