ADVAnCED PARAMETERS
35. S2 switch - associations sent to 4th and 5th association groups
This parameter determines which actions result in sending com-
mands to devices associated in 4th and 5th association group.
All actions are active by default.
Available settings:
1
- ignore turning on with 1 click of the switch
2
- ignore turning off with 1 click of the switch
4
- ignore holding and releasing the switch*
8
- ignore double click of the switch**
Default setting:
0
Parameter size:
1
[byte]
36. S2 switch - Switch ON value sent to 4th and 5th association
groups
This parameter defines value sent with Switch On command to devic-
es associated in 4th and 5th association group.
Available settings:
0-255
- sent value
Default setting:
255
Parameter size:
2
[bytes]
37. S2 switch - Switch OFF value sent to 4th and 5th association
groups
This parameter defines value sent with Switch OFF command to de-
vices associated in 4th and 5th association group.
Available settings:
0-255
- sent value
Default setting:
0
Parameter size:
2
[bytes]
38. S2 switch - Double Click value sent to 4th and 5th association
groups
This parameter defines value sent with Double Click command to de-
vices associated in 4th and 5th association group.
Available settings:
0-255
- sent value
Default setting:
99
Parameter size:
2
[bytes]
40. Reaction to General Alarm
This parameter determines how the device will react to General Alarm
frame.
Available settings:
0
- alarm frame is ignored
1
- turn On after receiving the alarm frame
2
- turn OFF after receiving the alarm frame
3
- flash after receiving the alarm frame
Default setting:
3
Parameter size:
1
[byte]
NOTE
Parameter 35 values
may be combined, e.g.
1+2=3 means that as-
sociations for turning
On and OFF are not
sent.
i
NOTE
*Hold and release is
inactive when param-
eter 20 is set to 1 or 2.
**Double click is inac-
tive when parameter
20 is set to 1.
i
Summary of Contents for Switch 2 FGS-2 3 Series
Page 2: ......