ADVAnCED PARAMETERS
41. Reaction to Flood Alarm
This parameter determines how the device will react to Flood Alarm
frame.
Available settings:
0
- alarm frame is ignored
1
- turn On after receiving the alarm frame
2
- turn OFF after receiving the alarm frame
3
- flash after receiving the alarm frame
Default setting:
2
Parameter size:
1
[byte]
42. Reaction to CO/CO2/Smoke Alarm
This parameter determines how the device will react to CO, CO2 or
Smoke frame.
Available settings:
0
- alarm frame is ignored
1
- turn On after receiving the alarm frame
2
- turn OFF after receiving the alarm frame
3
- flash after receiving the alarm frame
Default setting:
3
Parameter size:
1
[byte]
43. Reaction to Heat Alarm
This parameter determines how the device will react to Heat Alarm
frame.
Available settings:
0
- alarm frame is ignored
1
- turn On after receiving the alarm frame
2
- turn OFF after receiving the alarm frame
3
- flash after receiving the alarm frame
Default setting:
1
Parameter size:
1
[byte]
44. Flashing alarm duration
This parameter allows to set duration of flashing alarm mode.
Available settings:
1-32000
(1-32000s, 1s step) - duration
Default setting:
600
(10min) Parameter size:
2
[bytes]
50. First channel - power reports
This parameter determines the minimum change in consumed power
that will result in sending new power report to the main controller.
Available settings:
0
- reports are disabled
1-100
(1-100%) - change in power
Default setting:
20
(20%)
Parameter size:
1
[byte]