ADVAnCED PARAMETERS
The Switch 2 allows to customize its operation to user’s needs. The
settings are available in the FIBARO interface as simple options that
may be chosen by selecting the appropriate box.
In order to configure the Switch 2 (using the Home Center controller):
1. Go to the device options by clicking the icon:
2. Select the „Advanced” tab.
#10: Advanced parameters
9. Restore state after power failure
This parameter determines if the device will return to state prior to
the power failure after power is restored.
Available settings:
0
- the device does not save the state prior to
the power failure and returns to „off” position
1
- the device restores its state prior to the pow-
er failure
Default setting:
1
Parameter size:
1
[byte]
10. First channel - operating mode
This parameter allows to choose operating for the 1st channel con-
trolled by the S1 switch.
Available settings:
0
- standard operation
1
- delay On
2
- delay OFF
3
- auto On
4
- auto OFF
5
- flashing mode
Default setting:
0
Parameter size:
1
[byte]
11. First channel - reaction to switch for delay/auto ON/OFF
modes
This parameter determines how the device in timed mode reacts to
pushing the switch connected to the S1 terminal.
Available settings:
0
- cancel mode and set target state
1
- no reaction to switch - mode runs until it ends
2
- reset timer - start counting from the beginning
Default setting:
0
Parameter size:
1
[byte]