Information about this operating manual 

Please read the operating instructions and familiarise yourself with the unit prior to using it for the first 
time. Adhere to the safety information for the correct and safe use of the unit. 
 

Intended use 

The FIAP Bio Active, in the following text termed unit, is a flow-through filter system with integrated 
UVC clarifying unit for the bio-mechanical filtering of normal pond water at temperatures from + 4°C to 
+ 35°C. The flow-through filter system is only suitable for private use and must exclusively be used for 
cleaning garden ponds with or without fish population. 
 

Use other than that intended 

Danger to persons can emanate from this unit if it is not used in accordance with the intended use and 
in the case of misuse. If used for purposes other than that intended, our warranty and operating permit 
will become null and void. 
 

CE Manufacturer's Declaration 

We declare conformity in the sense of the EC directive, EMC directive (89/336/EEC) as well as the low 
voltage directive (73/23/EEC). The following harmonised standards apply: 
EN 55014-2, EN 55015, EN 60598-1, EN 60335-1, EN 60335-2-41, EN 60598-2-1, EN 61000-3-2, EN 
61000-3-3, EN 61547 
 

Safety information 
For safety reasons, children and young persons under 16 years of age as well as persons who 
cannot recognise possible danger or who are not familiar with these operating instructions, are 
not permitted to use the unit! 

Please keep these operating instructions in a safe place! Also hand over the operating instructions 
when passing the unit on to a new owner. Ensure that all work with this unit is only carried out in 
accordance with these instructions. 
The combination of water and electricity can lead to danger to life and limb, if the unit is incorrectly 
connected or misused. 

Attention! Dangerous ultra-violet radiation. 

The radiation of the UVC lamp is dangerous to eyes and skin! For this reason, the unit can only be 
switched on with the housing fitted (safety switch). Never operate the unit lamp outside of its housing. 
Never immerse the filter in water! Always disconnect the power supply of these and all other units 
located in water prior to performing work on the units! Only operate the units when plugged into an 
earthed socket. The latter must have been installed in accordance with the valid national regulations. 
Ensure that the protective earth wire is led to the unit. Only use cables approved for outside use. Never 
use installations, adapters, extension or connection cables without protective earth contact! The cross 
section of power connection cables must not be smaller than the rubber cables identified with H05 
RNF. Extension cables must meet DIN VDE 0620. Ensure that the units are supplied with a rated 
residual current of max. 30 mA via a residual current-operating system (FI or RCD resp.). Electrical 
installations at garden ponds and swimming pools must meet the international and national regulations 
valid for installers. Compare the electrical values of the power supply with those on the type plate on 
the packaging or on the units. Protect the connection cable when burying to avoid damage. Protect the 
plug connections and all connection points from moisture. Never operate the unit if the cable or 
housing are defective! Disconnect the power! The power connection cables of these units cannot be 
replaced. Replace the units (unit components) concerned if the cables are damaged. Do not carry or 

FIAP Bio Active  

 
 

 

Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045   

8

 

FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen 

Tel: 09628 9213 0; Fax: 09628 9213 30; 

www.fiap.com

 

 

 

pull the units by their connection cables. Never open the unit housings or their attendant components, 
unless this is explicitly mentioned in the operating instructions. Never carry out technical changes to 
the units. Only use original spare parts and accessories for the units. Only allow authorised customer 
service outlets to perform repairs. For your own safety, consult a qualified electrician if you have 
questions or encounter problems! Do not operate the units if persons are in the water! Never run the 
units without water! Never use the pump for fluids other than water! Ensure that no leaks at the filter 
can occur. Danger of completely emptying the pond. 
 

Installation, assembly 

Cut the stepped hose adapters such that the connection opening coincides with the hose diameter. 
This helps avoid pressure loss. 
Ensure that the unit is placed at a flood protected place and on firm ground. Keep a minimum distance 
from the pond edge of 2 m. Ensure unrestricted access to the cover to be able to carry out work on the 
unit. 
Push or turn the hose onto the stepped hose adapter, secure with the hose clip, then screw the 
stepped hose adapter on the water inlet. 
Ensure that the drain pipes for the water return are laid towards the pond with a suitable incline (>1 %) 
FIAP recommends to return the clean water into the pond via a water course to additionally enrich the 
water with oxygen. 
An optional adapter set is available for the cleaning outlet. For this purpose, remove the cover cap 
from the cleaning outlet. Push the union nut over the hose, slide the stepped hose adapter without 
thread onto the hose end and secure with the hose clip. Connect the stepped hose adapter with union 
nut and flat seal to the cleaning outlet. Push the stepped hose adapter with thread onto the other hose 
end, secure with the hose clip and screw on the cover cap including flat seal. Lay the hose with a 
suitable incline (>1 %) towards the sewage system or to a flower bed. 
 

Start-up 
Important: 

Adhere to the safety information given above! Check the correct seating of hoses and 

cover cap prior to starting up. Never operate the UVC clarifying unit without water. 
Switch on the pump and wait until the filter housing is filled with water. Check all connections for leaks. 
Connect the power plug of the UVC clarifying unit, the blue control lamp is lit. In the event of 
overheating, the temperature monitor switches the UVC clarifying unit off automatically, the UCF 
clarifying unit automatically switches on again once it has cooled down. 

Note: 

After a new installation, the unit only reaches its full biological cleaning effect after a few weeks. 

The full effect on bacteria is only reached as from a water temperature of + 10 °C. 

Switch the UVC clarifying unit off 

Disconnect the power supply to switch off the unit. 
 

Maintenance and cleaning 
Attention! Always disconnect the power plug from the UVC clarifying unit prior to starting 
cleaning and maintenance work! 

Adhere to the safety information given above! Check and clean the water outlet into the pond at regular 
intervals. Clean the filters at regular intervals (e.g. every four weeks), however, at the latest when 
cloudy or dirty water from the water outlet returns to the garden pond. Carry out quick cleaning first. 
Should this prove insufficient, clean the entire unit. Never use chemical cleaning agents. 
 
 
 
 
 

Summary of Contents for Bio Active

Page 1: ...r bernehmen wir keine Haftung WEEE Reg Nr DE78152045 2 FIAP GmbH Jakob Oswald Str 16 92289 Ursensollen Tel 09628 9213 0 Fax 09628 9213 30 www fiap com Art Nr Bezeichnung mit UV C Wasserdurchsatz l h A...

Page 2: ...es mit denen des Typenschildes auf der Verpackung bzw auf den FIAP Bio Active Technische nderungen vorbehalten F r Druckfehler bernehmen wir keine Haftung WEEE Reg Nr DE78152045 4 FIAP GmbH Jakob Oswa...

Page 3: ...htem Druck im Uhrzeigersinn bis zum Anschlag drehen so dass die Pfeile am Ger tekopf und am Geh use aufeinander zeigen UVC Lampe wechseln F r eine optimale Filterleistung sollten Sie die UVC Lampe nac...

Page 4: ...The power connection cables of these units cannot be replaced Replace the units unit components concerned if the cables are damaged Do not carry or FIAP Bio Active Technische nderungen vorbehalten F...

Page 5: ...mend to replace the UVC lamp after approx 6000 operating hours Important Only use lamps the designation and rating of which match the information on the type plate Pull out and replace the UVC lamp St...

Page 6: ...halten F r Druckfehler bernehmen wir keine Haftung WEEE Reg Nr DE78152045 12 FIAP GmbH Jakob Oswald Str 16 92289 Ursensollen Tel 09628 9213 0 Fax 09628 9213 30 www fiap com correspondre aux r glements...

Page 7: ...engager dans les rainures du verrouillage ba onnette En exer ant une l g re pression tourner la t te de l appareil dans le sens des aiguilles d une montre jusqu la but e afin que les deux fl ches se t...

Page 8: ...schermd aan zodat beschadigingen uitgesloten zijn FIAP Bio Active Technische nderungen vorbehalten F r Druckfehler bernehmen wir keine Haftung WEEE Reg Nr DE78152045 16 FIAP GmbH Jakob Oswald Str 16 9...

Page 9: ...gleuven van de bajonetsluiting grijpen Draai de kop van het apparaat onder lichte druk met de wijzers van de klok mee tot aanslag zodat de pijlen op de kop van het apparaat en de behuizing recht tege...

Page 10: ...en Tel 09628 9213 0 Fax 09628 9213 30 www fiap com prescripciones de montaje internacionales y nacionales Compare los datos el ctricos de la red de alimentaci n con los datos en la placa de datos t cn...

Page 11: ...ire la cabeza del equipo ejerciendo una ligera presi n en el sentido de las agujas del reloj hasta el tope de forma que las dos flechas en la cabeza del equipo y en la caja indiquen una a la otra Camb...

Page 12: ...gsledningerne til disse apparater kan ikke udskiftes Hvis ledningerne beskadiges skal de tilsvarende apparater apparatdele udskiftes B r eller tr k ikke apparaterne i tilslutningsledningerne bn aldrig...

Page 13: ...es p rer hvis betegnelse og effektangivelser stemmer overens med oplysningerne p typeskiltet Tag UVC p ren ud og udskift den Opbevaring overvintring Ved vandtemperaturer under 8 C eller senest ved for...

Page 14: ...Reg Nr DE78152045 28 FIAP GmbH Jakob Oswald Str 16 92289 Ursensollen Tel 09628 9213 0 Fax 09628 9213 30 www fiap com wyzwalane przez pr d up ywowy maksymalnie 30 mA Instalacje elektryczne staw w ogro...

Page 15: ...przekr ci j w kierunku zgodnym z ruchem wskaz wek zegara strza ki a do oporu tak aby strza ki na g owicy urz dzenia i obudowie by y skierowane do siebie Wymiana lampy ultrafioletowej Utrzymanie optym...

Page 16: ...ci ze z suvky P vodn s ov veden t chto p stroj nelze vym nit P i po kozen veden se mus odpov daj c p stroje sou sti vym nit Nenoste resp netahejte p stroje na p vodn ch veden ch Neotev rejte FIAP Bio...

Page 17: ...u souhlas s daji na typov m t tku Vyt hn te a vym te z ivku UVC Ulo en P ezimov n P i teplot ch vody pod 8 C nebo nejpozd ji tehdy kdy se o ek vaj mrazy mus te uv st za zen mimo provoz Vypus te pr tok...

Page 18: ...AP Bio Active 4 C 35 C EC 89 336 EEC EMC 73 23 EEC 1000 EN 55014 2 EN 55015 EN 60598 1 EN 60335 1 EN 60335 2 41 EN 60598 2 1 EN 61000 3 2 EN 61000 3 3 EN 61547 16 H05 RNF DIN VDE 0620 30 A FIAP Bio Ac...

Page 19: ...mbH Jakob Oswald Str 16 92289 Ursensollen Tel 09628 9213 0 Fax 09628 9213 30 www fiap com 6000 8 C FIAP Bio Active Technische nderungen vorbehalten F r Druckfehler bernehmen wir keine Haftung WEEE Reg...

Page 20: ...proteja conducta de leg tur a a nc t s se exclud orice deteriorare Se va proteja stecherul de FIAP Bio Active Technische nderungen vorbehalten F r Druckfehler bernehmen wir keine Haftung WEEE Reg Nr D...

Page 21: ...s intre n canalele nchiz torului baionet Se va r suci cap tul dispozitivului n sensul acelor de ceas exercit nd o presiune u oar p n se opre te a a nc t s ge ile de la cap tul dispozitivului i de la...

Page 22: ...000 2831 1 FIAP F llpaket Bio Active 10 000 FIAP fill package Bio Active 10 000 2832 1 FIAP F llpaket Bio Active 18 000 25 000 FIAP fill package Bio Active 18 000 2827 1 FIAP Gl hleuchte 9 W FIAP repl...

Reviews: