8
LIGHTING INSTRUCTIONS
1-
STOP!
Read all warnings and safety information in this manual.
2-
WARNING:
BE SURE THAT THE CHIMNEY DAMPER IS
FULLY OPEN!
LIGHTING THE PILOT
3- Push in the gas control knob slightly, and turn it in a clockwise
direction to the OFF position. DO NOT FORCE! NEVER USE
ANY TOOL, TO ROTATE THE GAS CONTROL KNOB! If gas
control knob will not rotate, contact your installer or the
Service Center. ( SEE FIGURE 14 )
FIGURE 14
4-
Slowly, turn on the gas, at the manual shut-off valve, beside the
fireplace.
5-
STOP! WAIT FIVE ( 5 ) MINUTES!
6-
If you smell gas,
STOP!
7-
Turn off the gas at the manual shut-off valve, and recheck all gas
connections for leaks. Do not continue until all leaks are
corrected. Once you are assured that there are no leaks, proceed
with step eight ( 8 ).
8-
Locate the pilot.
Pilot
is located at the rear, right-hand side of the
unit. ( SEE FIGURE 13
)
9-
While holding a burning, long hearth match or hand fire starter,
near the pilot head, depress the gas control knob all the way
down, and turn the knob in a counter-clockwise direction, to the
pilot position. Continue to hold the gas control knob down for
approximately one ( 1 ) minute, after the pilot is lit.
10-
Pilot should remain lit, and control knob should pop back out
when released. If not, repeat the aforementioned steps. If pilot
ignition does not take place, contact your installer or the
Fiamma
Service Center.
LIGHTING THE BURNER SYSTEM
See the instructions that are packaged with the remote, and/or
instructions on Page 6, of this manual.
WARNING:
If ignition does not take place,
TURN THE GAS OFF
, at
the manual shut-off valve, and wait five ( 5 ) minutes, before attempting
to relight the appliance. If after repeated attempts, the appliance does
not ignite, contact your installer, or the
fire
gear Service Center.
PILOT FLAME ADJUSTMENT
FIGURE 15
The pilot flame should be a soft blue in color, and should surround the
ODVW´RIWKHWKHUPRFRXSOHWLS
MAINTENANCE & SERVICE
Your
Verona Burner
should be thoroughly
inspected on a regular basis, at least once a year, by a qualified
installer.
At the beginning of each heating season, the system should be
checked as follows:
1-
Check the chimney flue or vent pipe to make sure that the flue is
drawing properly, and that any vent pipe connections are tight.
2-
Check to see that there are no blockages at the chimney or vent
termination.
3-
Check for creosote, or soot build up in chimney or vents, and
clean if necessary.
4-
Pilot and burners should be inspected annually, at the beginning
of each heating season.
ADJUSTMENTS
The burner system has been adjusted for proper operation at the
factory. No adjustment is necessary, other than altitude de-rate, or
pilot flame.
NEVER
enlarge valve orifices or burner ports.
PILOT FLAME
MUST SURROUND
THERMOCOUPLE
TIP AS SHOWN
PILOT FLAME
THERMOCOUPLE
PILOT
ADJUSTMENT
SCREW