9  

 

 

  

 

SYSTEM

 

TROUBLE SHOOTING

 

 

PROBLEM OBSERVED 

  

POSSIBLE CAUSE 

  

CORRECTIVE MEASURE 

 

 

 

 

 

Gas odor during set up 

 

Gas leak 

 

See " What to do if you smell gas " page 1 

 

 

 

 

Check all gas connections 

 

 

 

 

 

Gas odor before first ignition 

 

Gas leak 

 

See " What to do if you smell gas " page 1 

 

 

 

 

Check all gas connections 

Pilot will not ignite, or will not stay lit 

 

No gas to pilot 

 

Make sure gas is on, in pilot position 

 

 

Thermocouple not hot 

 

Depress valve knob for at least 1 minute 

 

 

Improper pilot flame adjustment 

 

See Pilot Characteristics - adjust flame 

 

 

Loose connections on thermocouple 

 

Check gas connections 

 

 

Faulty pilot or thermocouple 

 

Replace Safety Pilot 

 

 

Faulty Valve 

 

Replace Valve 

 

 

 

 

 

Delayed ignition 

 

Low gas pressure 

 

Check gas supply pressure 

 

 

Clogged or dirty burner ports 

 

Clean burner ports 

 

 

Blocked orifice 

 

Check orifice opening 

 

 

Faulty Valve 

 

Replace Valve 

 

 

 

 

 

Burner does not light but pilot remains on 

 

Low gas pressure 

 

Check gas supply pressure 

 

 

Clogged or dirty burner ports 

 

Clean burner ports 

 

 

Blocked orifice 

 

Check orifice opening 

 

 

Faulty pilot or thermocouple 

 

Replace Safety Pilot 

 

 

Faulty Valve 

 

Replace Valve 

 

 

 

 

 

Burner lights but does not stay lit 

 

Low gas pressure 

 

Check gas supply pressure 

while pilot remains on 

 

Faulty Valve 

 

Replace Valve 

 

 

Faulty pilot or thermocouple 

 

Replace Safety Pilot 

 

 

Clogged or dirty burner ports 

 

Clean burner ports  

 

 

 

 

 

Burner & pilot light but will not stay on 

 

Low gas pressure 

 

Check gas supply pressure 

 

 

Not enough fresh air for pilot 

 

Open door or window - ventilate 

 

 

Faulty Valve 

 

Replace Valve 

 

 

Faulty pilot or thermocouple 

 

Replace Safety Pilot 

 

 

Clogged or dirty burner ports 

 

Clean burner ports  

 

 

Remote control overheating 

 

Move away from flame 

 

 

Remote control batteries failing 

 

Replace batteries 

 

 

 

 

 

Incorrect burner flame 

 

Incorrect gas supply or pressure 

 

Check gas supply pressure 

 

 

Blocked orifice 

 

Check orifice opening 

 

 

Clogged or dirty burner ports 

 

Clean burner ports 

 

 

Faulty Valve 

 

Replace Valve 

 

 

High altitude  

 

Adjust orifice size for altitude 

 

 

 

 

 

Backfire of burner 

 

Blocked orifice 

 

Check orifice opening 

 

 

Clogged or dirty burner ports 

 

Clean burner ports 

 

 

Low gas pressure 

 

Check gas supply pressure 

 

 

 

 

 

Appliance produces unwanted odors 

 

Vapors from paint, hair spray, glues, etc 

 

Ventilate room 

 

 

Initial burn off of manufacturing chemicals 

 

Ventilate room 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Whistle noise from appliance 

 

Air in gas line 

 

Bleed lines 

 

 

Control knob not in fully open position 

 

Open control knob to full open 

 

 

Spiral gas flex line 

 

Replace gas feed line 

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for VERONA

Page 1: ...l with the appliance CONSUMER Retain this manual for future reference WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING This appliance must be installed only in a solid fuel burning fireplace with a working flue and constructed of non combustible materials This unit is NOT for use with so...

Page 2: ...operating the appliance During manufacturing fabrication and shipping various components of this appliance are treated with certain oils films or bonding agents These chemicals ARE NOT harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance This may possibly cause headaches and eye or lung irritation This is a normal and temporary occu...

Page 3: ...fitter WARNING Improper installation adjustment alteration service or maintenance can cause property damage personal injury or ORVV RI OLIH 5HIHU WR WKH RZQHU V LQIRUPDWLRQ PDQXDO SURYLGHG with this appliance Installation and service must be performed by a qualified installer service agency or the gas supplier HIGH ALTITUDE DERATE In the U S A input BTU shall be de rated 4 1 orifice size per 1000 ...

Page 4: ...WARNING Gas supply system must be installed in accordance with the U S National Fuel Gas Code This appliance and its individual shut off valve must be disconnected from the gas supply piping system during any system pressure test in excess of PSI 3 5 KPA Use a system manual shut off valve to shut off the gas supply to this gas appliance before continuing with installation procedures FIGURE 2 VERON...

Page 5: ...s to brass require Teflon tape or pipe dope INSTALLING THE APPLIANCE INTO THE FIREPLACE 1 Place the VERONA BURNER into the fireplace unit is packaged completely assembled The unit should be centered from both side to side and front to back SEE FIGURE 2 3 2 Using an adjustable wrench and turning in a clockwise direction DWWDFK D HPDOH ODUH 0DOe Flare Brass Reducer Fitting included on some models to...

Page 6: ...r 2 Connect the BLACK 18 gauge wire with the 1 4 female terminal from the receiver to the BLACK wire with the 1 4 male terminal from the valve solenoid 3 Connect the RED 18 gauge wire with the 1 4 female terminal from the receiver to the RED ZLUH ZLWK WKH PDOH WHUPLQDO from the valve solenoid IMPORTANT NOTE Operation of these controls is dependent upon which wire is attached to which terminal If o...

Page 7: ......

Page 8: ...actly when lighting the appliance BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the floor as LP gas is heavier than air and will settle to the floor Use only your hand to rotate the gas control knob Never use tools If the knob will not turn by hand do not try to repair it call qualified service technician or installer Force or attempted repair may result in a fir...

Page 9: ...does not take place contact your installer or the Fiamma Service Center LIGHTING THE BURNER SYSTEM See the instructions that are packaged with the remote and or instructions on Page 6 of this manual WARNING If ignition does not take place TURN THE GAS OFF at the manual shut off valve and wait five 5 minutes before attempting to relight the appliance If after repeated attempts the appliance does no...

Page 10: ...oes not stay lit Low gas pressure Check gas supply pressure while pilot remains on Faulty Valve Replace Valve Faulty pilot or thermocouple Replace Safety Pilot Clogged or dirty burner ports Clean burner ports Burner pilot light but will not stay on Low gas pressure Check gas supply pressure Not enough fresh air for pilot Open door or window ventilate Faulty Valve Replace Valve Faulty pilot or ther...

Page 11: ...ms the defect and approves the claim Fiamma will replace such parts without charge If you are required to return defective parts transportation charges must be prepaid Fiamma will require form of payment for the return of the product There are no other express warranties except as set forth herein and any applicable implied warranties of merchantability and fitness are limited in duration to the p...

Reviews: