6
REMOTE SYSTEMS
All burner systems are capable of operation with a latching
solenoid, remote control system or Variable Flame Height motor.
Label all wires prior to disconnection when servicing controls. Wiring
errors can cause improper and dangerous operation. Verify proper
operation after servicing.
All VERONA Vented Burner Systems use:
1- The American Flame, AF-1000 Series Valves ( AF-1010 shown
here with remote solenoid shown separately in diagram ). All
systems use a safety pilot, with a thermocouple.
( SEE FIGURE 4 & 5 )
2- One of the following, latching solenoid, battery operated Variable Flame
Height systems:
A-
On/off hand held remote
B-
Variable Flame remote
One is necessary for operation
with any of the above remote systems.
CONNECTING THE RECEIVER TO THE VALVE
1-
The wire harness should already be installed, in the terminal
block, on the rear of the remote receiver
.
2-
Connect the BLACK 18 gauge wire, with the 1/4" female terminal,
from the receiver, to the BLACK wire with the 1/4" male terminal,
from the valve solenoid.
3-
Connect the RED 18 gauge wire, with the 1/4" female terminal,
from the receiver, to the RED
ZLUHZLWKWKH´PDOHWHUPLQDO
from the valve solenoid.
IMPORTANT NOTE:
Operation of these controls is dependent upon
which wire is attached to which terminal. If operation does not
correspond to operating buttons on the transmitter, reverse the wire
installation at the receiver, or at
the transmitter.
NOTE
: Up to 6.3 VDC of power is provided at the receiver terminal.
FIGURE 4
BEFORE TURNING KNOB
TO "ON" POSITION,
PRESS THE OFF BUTTON
ON THE REMOTE !
FIGURE 6
FIGURE 7
One Side of the Verona has a steel cover with 2 Phillips screws, This conceals rhe Remote Receiver ( FIGURE 6 )
This is an Inside View of the Reciever behinde the steel cover ( FIGURE 7 ) To replace 4 AA Batteries, remove this cover
and gently pull out the reciever. Replace batteries and cover.
FIGURE 5
NOTE: The Verona 42 has Receiver on the side of
Gas Valve on one side
Summary of Contents for VERONA