Positioning unit

Date: 08/02/21

File: Servo3M_M12_ing.doc

page 4/8

Power supply

a) Before connecting the unit, check that the power supply tension is within the permitted limits and that it
corresponds to the one indicated on the tag.
b) Carry out the electrical connections with the instrument disconnected.
c) For the power line to instruments and sensors, a power supply line separate from that of the power is
required : it is necessary to use an isolating transformer.
d) The power line should provide a device that separates the set fuses of the instruments and should not be
used to regulate relays, contactors, etc.
e) If the network tension is very disordered (ex. from the change-over of the power units, motors, inverters,
welders, etc.), use the appropriate filters of the network.
f) If an earth connection is needed, ensure that the plant has an adequate grounding system: tension
between neutral and earth <1V and the resistance <6 Ohm.

Gear motor assembly

Two M4 screws can be applied to the two M4x12 brass inserts: this is necessary in case the servo motor
must make many maneuvers or is used continuously.
The diameter Ø20 millimeter (50mm deep) hollow shaft  is applied to the driving shaft of the machine.
Ensure that the hollow shaft is perpendicular to the support base.
Lock the hollow shaft onto the machine shaft using the M4 screw on the clamping ring.
Note: The gear motor does not have parts that need maintenance or oiling.

If necessary, protect the unit from: dust, water, collisions, extreme temperatures.
Manually turn the shaft of the reducer using the clamping ring (tightened on the hollow shaft)
only if necessary.
Do not exceed permitted torque.
Do not dismantle or open the unit, particularly the part of the reducer.
Do not pierce/modify the container or the hollow shaft.

POTENTIOMETRIC

 

VERSION

 Before assembling the SERVO, it is fundamental to place the shaft of the

machine and the shaft of the SERVO in the correct position, for example half way or towards the end, in a
way that there is correlation between the position of the SERVO and that of the machine. To do that, the
motion of the hollow shaft of the SERVO should be serially commanded by the control unit (PLC, PC, etc): do
not rotate the shaft by hand.
The calculation of the number of turns that the hollow shaft has to complete to achieve the total motion of the
machine is determined by multiplying the reduction ratio of the reducer of the potentiometer by the number of
turns of the potentiometer itself (total reduction ratio = R).
In case that the maximum number of allowed rotations by the shaft is exceeded, a mechanical clutch
intervenes to safeguard the potentiometer transducer.

Note: the SERVO is provided with the hollow shaft and the potentiometer positioned half way.

ELECTRICAL CONNECTION

Disconnect from power supply before connecting/disconnecting the equipment/machinery.
The connecting cables must be kept separate from the power lines or from electromagnetic
interference sources.
Pay careful attention to the electrical connections: any failure caused by a faulty connection
will render the guarantee null and void.
The power supply must be in the permitted range, a higher range could damage the
equipment.

Remove the 3 closing screws of the cover to access the terminal box.
Carry out the connections according to the following figure:

Summary of Contents for SERVO3M

Page 1: ...Positioning unit Date 08 02 21 File Servo3M_M12_ing doc page 1 8 SERVO3M USER AND MAINTENANCE MANUAL ...

Page 2: ...for the storage of the device Avoid environments with excessive humidity and those exposed to harsh weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Maintenance The in...

Page 3: ...open PROFIBUS DP For electrical connection the power supply cable and the communications cables are separate the standard version of the SERVO 3M has 3 cable glands for input and output 2x PG9 1x PG7 an M12 T connector is available as option for power instead of the PG7 cable gland Installation Before installing the instrument read the following warnings a Connect the instrument strictly following...

Page 4: ...amping ring tightened on the hollow shaft only if necessary Do not exceed permitted torque Do not dismantle or open the unit particularly the part of the reducer Do not pierce modify the container or the hollow shaft POTENTIOMETRIC VERSION Before assembling the SERVO it is fundamental to place the shaft of the machine and the shaft of the SERVO in the correct position for example half way or towar...

Page 5: ...ANopen VERSION MALE FEMALE M12x1 CANOPEN CONNECTOR 1 not connected 2 not connected 3 CAN_GND 4 CAN_H 5 CAN_L B1 B2 CAN_L A1 A2 CAN_H COM CAN_GND 1 1 2 3 4 1 2 3 4 1 5 5 MALE FEMALE M12x1 PROFIBUS 1 not connected 2 PROFIBUS A 3 not connected 4 PROFIBUS B 2 3 4 1 2 3 4 1 5 5 MALE FEMALE M12x1 PROFIBUS 1 not connected 2 RS485 3 not connected 4 RS485 2 3 4 1 2 3 4 1 5 5 ...

Page 6: ... OF ADDRESS AND BAUD RATE Before setting SERVO it is necessary to set the address and baud rate of device using dip switch S1 and S2 as showed in the following table according to the model of SERVO used If the SERVO is the last node of net set at ON the dip switch S3 both switches 1 and 2 at ON IMPORTANT during this phase it is advisable to pay close attention to not damage the dip switch and the ...

Page 7: ... addresses from 1 to 127 The setting of baud rate is made by il dip switch 8 di S2 and the 2 dip switch of S1 By changing of address or baud rate is necessary to switch off and turn on the Servo S2 1 2 3 4 5 6 7 8 ON OFF OFF OFF OFF OFF OFF OFF 1 OFF ON OFF OFF OFF OFF OFF OFF 2 ON ON OFF OFF OFF OFF OFF OFF 3 OFF OFF ON OFF OFF OFF OFF OFF 4 etc etc S2 1 2 3 4 5 6 7 8 ADDRESS ON OFF OFF OFF OFF O...

Page 8: ...30 1 90 1 others on request Electrical connection 4 poles terminal board supply 4 poles terminal board field bus max 1 5mm2 Connections 1x PG7 cable gland for supply cable Ø 3 6mm or 1x optional M12 T connector for power supply 2x PG9 cable glands for field bus cable Ø 5 8mm Weight 1100g Protection level IP54 Working temperature 0 60 C Humidity 10 85 Directive 2014 30 EU Electromagnetic compatibil...

Reviews: