4. Commissioning
4−6
Festo P.BE−VTSA−44−EN en 0601a
The table below shows the effects of slow start−up pressuriza
tion when there are electric signals.
External
pilot air
Pressure
increase in
complete
supply
Pressure
increase in the
pilot air
(12/14)
Time point
when a valve
switches
Movement of
the actuator
branched after the start−up
valve for delayed build−up
of pressure
slow
slow
after
pressure
increase at (1)
fast
branched in front of the
start−up valve for delayed
build−up of pressure
slow
fast
before
pressure
increase at (1)
slow
Tab.4/1:
Effects of slow start−up pressurization
4.2
Manual override
You should use the manual override especially when commis
sioning the pneumatic system, in order to check the function
and operation of the valve or the valve−actuator combination.
By actuating the manual override, you can switch the valve
without an electric signal. You only need to switch on the
compressed air supply.
Please note
If you use the VTSA valve terminal in a dusty environment,
Festo recommends that you protect the manual overrides
with cover caps type VAMC−S6−CS againt dirt and dust
when the valve terminal has been commisssioned. At the
same time the manual overrides are protected against
incorrect use.
Summary of Contents for VTSA Series
Page 2: ......
Page 8: ...Contents and general instructions VI Festo P BE VTSA 44 EN en 0601a...
Page 16: ...Contents and general instructions XIV Festo P BE VTSA 44 EN en 0601a...
Page 17: ...Summary of components 1 1 Festo P BE VTSA 44 EN en 0601a Chapter 1...
Page 44: ...1 Summary of components 1 28 Festo P BE VTSA 44 EN en 0601a...
Page 45: ...Fitting 2 1 Festo P BE VTSA 44 EN en 0601a Chapter 2...
Page 60: ...2 Fitting 2 16 Festo P BE VTSA 44 EN en 0601a...
Page 61: ...Installation 3 1 Festo P BE VTSA 44 EN en 0601a Chapter 3...
Page 92: ...3 Installation 3 32 Festo P BE VTSA 44 EN en 0601a...
Page 93: ...Commissioning 4 1 Festo P BE VTSA 44 EN en 0601a Chapter 4...
Page 109: ...Maintenance and conversion 5 1 Festo P BE VTSA 44 EN en 0601a Chapter 5...
Page 133: ...Technical appendix A 1 Festo P BE VTSA 44 EN en 0601a Appendix A...
Page 147: ...Supplementary summary of components B 1 Festo P BE VTSA 44 EN en 0601a Appendix B...
Page 159: ...Index C 1 Festo P BE VTSA 44 EN en 0601a Appendix C...
Page 160: ...C Index C 2 Festo P BE VTSA 44 EN en 0601a Contents C Index C 1...