1. Summary of components
1−19
Festo P.BE−VTSA−44−EN en 0601a
Restrictions:
The exhaust flow is restricted by the pressure regulator.
The pressure regulator cannot be set in the exhaust state,
e.g. the pressure regulator for channel 4 cannot be set if
the valve pressurizes in switch position from channel 1 to
channel 2 and exhausts from channel 4 to channel 5.
Examples of application:
If two different working pressures are required at connec
tions 2 and 4 instead of the operating pressure of the
valve terminal:
If it is not possible to use the reversible pressure
regulator, e.g. when 2x3/2−way valves with ducted
exhaust 82/84 or when a throttle plate is used.
Reversible AB pressure
regulator (identifier
R5−...−6 and R5−...−10)
Mode of operation:
With the reversible pressure regulator the supply air (chan
nel 1) is divided and passed directly to both pressure regu
lators. In each case the regulated air is present in channels 3
and 5 on the valve. The valve is therefore operated revers
ibly (see fig.). This means:
channel 3 passes the working pressure to connection 2
channel 5 passes the working pressure to connection 4.
The following example shows the following switching
position:
The supply air in channel 1 is passed in the pressure
regulating plate to pressure regulators A and B, regulated
there and then passed to connections 3 and 5 on the valve.
In the valve the supply air is passed to connection 2 on the
manifold block. The exhaust is passed via channel 4 in the
pressure regulator plate and split there to channels 3 and 5
and exhausted.
Summary of Contents for VTSA Series
Page 2: ......
Page 8: ...Contents and general instructions VI Festo P BE VTSA 44 EN en 0601a...
Page 16: ...Contents and general instructions XIV Festo P BE VTSA 44 EN en 0601a...
Page 17: ...Summary of components 1 1 Festo P BE VTSA 44 EN en 0601a Chapter 1...
Page 44: ...1 Summary of components 1 28 Festo P BE VTSA 44 EN en 0601a...
Page 45: ...Fitting 2 1 Festo P BE VTSA 44 EN en 0601a Chapter 2...
Page 60: ...2 Fitting 2 16 Festo P BE VTSA 44 EN en 0601a...
Page 61: ...Installation 3 1 Festo P BE VTSA 44 EN en 0601a Chapter 3...
Page 92: ...3 Installation 3 32 Festo P BE VTSA 44 EN en 0601a...
Page 93: ...Commissioning 4 1 Festo P BE VTSA 44 EN en 0601a Chapter 4...
Page 109: ...Maintenance and conversion 5 1 Festo P BE VTSA 44 EN en 0601a Chapter 5...
Page 133: ...Technical appendix A 1 Festo P BE VTSA 44 EN en 0601a Appendix A...
Page 147: ...Supplementary summary of components B 1 Festo P BE VTSA 44 EN en 0601a Appendix B...
Page 159: ...Index C 1 Festo P BE VTSA 44 EN en 0601a Appendix C...
Page 160: ...C Index C 2 Festo P BE VTSA 44 EN en 0601a Contents C Index C 1...