SDE3−...
Festo SDE3−... 0604a English
53
Type SDE3−...
V1..−...
B2..−...
D2..−...
D6..−...
D10..−...
Operating voltage range
[VDC]
15 ... 30 (permitted residual ripple max.: 10 %)
Idle current
[mA]
max. 35 (approx. 30 typ.)
Ready−state delay
[ms]
max. 500
(with start−up incorrect pulse suppression)
Switching outputs
Max. output current
Switchable capacity
Switching time (on/off )
[mA]
[nF]
[ms]
100
max. 100
max. 6 (3 typ.)
Protective functions
Inductive protective circuit
Protection against short circuit
Protection against polarity
reversal
Adapted to MZ, MY, ME coils
Pulsed
For all electrical connections
Protection class
IP65 (as per EN 60529)
Protection class
III (as per DIN VDE 0106−1)
Interference immunity
Interference emission
See conformity declaration www.festo.com
Vibration resistance
As per DIN/IEC68/EN60068 part 2−6:
0.35mm travel at 10 ... 60Hz,
5g acceleration at 60...150Hz
Shock resistance
As per DIN/IEC68/EN60068 part 2−27:
30g acceleration at 11ms duration (half−sine)
Max. permitted signal
cable length
[m]
30
Materials
Housing
Pushbuttons
Seals
Adapter plate
Plugs
Pneumatic connection
Cables
PA−reinforced PC
TPE−U
NBR / FPM
Steel (chromatized)
Brass (nickel−plated)
POM, brass (nickel−plated)
PUR
Fig.21
Summary of Contents for SDE3 series
Page 27: ...SDE3 Festo SDE3 0604a Deutsch 27 Bild 23 EDIT Modus ...
Page 28: ...SDE3 Festo SDE3 0604a Deutsch 28 Bild 24 TEACH Modus ...
Page 30: ...SDE3 Festo SDE3 0604a Deutsch 30 ...
Page 55: ...SDE3 Festo SDE3 0604a English 55 Fig 23 EDIT mode ...
Page 56: ...SDE3 Festo SDE3 0604a English 56 Fig 24 TEACH mode ...