OVEM
94
Festo – OVEM – 1407c English
7.2
Changing settings and values
Information such as settings and values can be changed,
è
Note
The last saved settings are retained in the event of a power failure.
7.3
Reset to factory setting
(also if the security code cannot be found)
Note
By resetting to factory settings, the current settings are lost. If required, make a note of
these settings before resetting.
To reset the vacuum suction nozzle to factory setting, proceed as follows:
1. Switch off the operating voltage.
2. Press all three setting elements (UP DOWN EDIT button) simultaneously and keep
them depressed.
3. Switch the operating voltage back on.
8
Maintenance and diagnostics
8.1
Maintenance
Switch off the following energy sources before cleaning the exterior of the device:
–
operating voltage
–
compressed air.
If necessary, clean the outside of the vacuum suction nozzle.
Permissible cleaning agents are soap suds (max. +60 °C) and all non-abrasive agents.
Check whether the air filter is contaminated.
The filter can be inspected visually through the transparent filter cover.