3. Set the desired time (in ms) with the UP/DOWN keys.
The value 0 corresponds to OFF, the ejector pulse is switched off.
4. Press the EDIT button to confirm the set value.
è
FORC is illuminated. The submenu for the function electrical manual override is active.
Electrical manual override
5. Actuate the solenoid valve via the electronic switching as follows:
A button: for vacuum solenoid valve ON/OFF
B button: for ejector pulse solenoid valve
6. Press the EDIT button to exit the submenu.
è
The vacuum suction nozzle is in the RUN mode.
6.3.4
[SPEC] – Set air saving function option (LS option), security code, evacuation and air
supply times
L
L
L
L
Fig. 16
Special menu (SPEC) (menu structure EDIT mode
è
The vacuum suction nozzle is in the EDIT mode and [Out A] is flashing.
1. Press the A button until the menu (SPEC) is selected.
è
[SPEC] flashes.
2. Press the EDIT button to confirm the selection.
è
[Option] flashes.
3. Select the desired setting LS option (ON: LS active; OFF: LS inactive) with the UP/DOWN keys.
4. Press the EDIT button to confirm the selection.
è
[Lock] flashes.