OVEM
Festo – OVEM – 1407c English
89
5. Set the desired security code with the UP/DOWN keys. (OFF = no protection).
Store the security code where it can be found again. If you forget the security code
è
Note
Monitoring of the evacuation and air supply times is deactivated in the factory.
6. Press the EDIT button to confirm the set value.
è
[msec], [SP], [max], [_|¯] flash.
7. Set the maximum evacuation time with the UP/DOWN keys. (OFF: monitoring of evacuation time is
deactivated)
8. Press the EDIT button to confirm the set value.
è
[msec], [SP], [max], [¯|_] flash
9. Set the maximum air supply time with the UP/DOWN keys. (OFF: monitoring of air supply time is
deactivated)
10.Press the EDIT button to confirm the set value.
è
The vacuum suction nozzle is in the RUN mode.
6.4
TEACH mode
In the TEACH mode, the switching variable (switching point or switching window) with and without air
saving function as well as the air supply and evacuation times can be taught.
Note
Before teaching, make sure that the desired switching function (window or threshold
comparator) and the desired hysteresis are set in the EDIT mode (
è
Threshold value comparator
Window comparator
The (taught) switching point is derived from the
average value of both teach points. Calculation
equation: SP = 1/2 (TP1 + TP2) If both teach
points are equal: SP = TP1 = TP2.
The taught switching window results from: SP
min
= smaller teach point (TP1 or TP2); SP
max
= lar
ger teach point (TP1 or TP2).
Position of the teach points (example)
Position of the teach points (example)
Tab. 11
Set switch variable
Summary of Contents for OVEM
Page 52: ...OVEM 52 Festo OVEM 1407c Deutsch Fig 23 SHOW Modus ...
Page 53: ...OVEM Festo OVEM 1407c Deutsch 53 Fig 24 EDIT Modus ...
Page 54: ...OVEM 54 Festo OVEM 1407c Deutsch Fig 25 TEACH Modus ...
Page 106: ...OVEM 106 Festo OVEM 1407c English Fig 23 SHOW mode ...
Page 107: ...OVEM Festo OVEM 1407c English 107 Fig 24 EDIT mode ...
Page 108: ...OVEM 108 Festo OVEM 1407c English Fig 25 TEACH mode ...