OVEM
62
Festo – OVEM – 1407c English
Features
Specification
Code
Pressure sensor, electrical
switching output
-2P
2 switching outputs PNP
-2N
2 switching outputs NPN
-PU
1 switching output PNP, 1 analogue output 0 … 10 V
-PI
1 switching output PNP, 1 analogue output 4 … 20 mA
-NU
1 switching output NPN, 1 analogue output 0 … 10 V
-NI
1 switching output NPN, 1 analogue output 4 … 20 mA
Alternative vacuum display
-
Bar (-B), inches Hg (-BN)
-B
bar
-W
Inches H
2
O
-H
Inch Hg
Tab. 1
Overview of variants
2
Fast commissioning with factory setting
The vacuum suction nozzle is shipped with the following factory settings:
Air-saving function with -CE/-OE: active
Switching characteristics of the electrical output: threshold value comparator
Switching element function of the electrical output: NO (normally open)
Additional factory settings
è
1. Mount the vacuum suction nozzle (
è
2. Connect the vacuum suction nozzle pneumatically (
è
3. Connect the vacuum suction nozzle electrically (
è
è
The vacuum suction nozzle can be placed in operation.
If you do not wish to use the factory setting, you can manually define a switching point for Out A or
Out B as follows: (
è
chapter 6.3.2, page 86). You can also teach switching points (
è
Summary of Contents for OVEM
Page 52: ...OVEM 52 Festo OVEM 1407c Deutsch Fig 23 SHOW Modus ...
Page 53: ...OVEM Festo OVEM 1407c Deutsch 53 Fig 24 EDIT Modus ...
Page 54: ...OVEM 54 Festo OVEM 1407c Deutsch Fig 25 TEACH Modus ...
Page 106: ...OVEM 106 Festo OVEM 1407c English Fig 23 SHOW mode ...
Page 107: ...OVEM Festo OVEM 1407c English 107 Fig 24 EDIT mode ...
Page 108: ...OVEM 108 Festo OVEM 1407c English Fig 25 TEACH mode ...