MS6(N)-SV-...-E-ASIS
Festo – MS6(N)-SV-...-E-ASIS – 1205NH English
57
14.5
Venting time
The following table shows the venting time in normal operation (N) and in the event of a fault (F) with
silencer UOS-1 ,
12 Accessories, at various volumes and operating pressures.
Note
The fault case (F) assumes the worst possible error in the valve’s interior (worst case).
Normal operation: N
Fault case: F
Operating pressure
3.5 bar
Operating pressure
6 bar
Operating pressure
10 bar
Venting time [s]
Venting time [s]
Venting time [s]
at 1.0 bar
at 0.5 bar
at 1.0 bar
at 0.5 bar
at 1.0 bar
at 0.5 bar
Volume [l]
2
N
(F)
0.1
(0.16)
0.2
(0.22)
0.24
(0.28)
0.3
(0.35)
0.3
(0.36)
0.4
(0.52)
10
N
(F)
0.3
(0.4)
0.45
(0.6)
0.55
(0.8)
0.7
(1.1)
0.7
(1.2)
0.9
(1.9)
20
N
(F)
0.5
(0.8)
0.85
(1.25)
1.0
(1.5)
1.3
(2.2)
1.4
(2.4)
1.7
(3.9)
40
N
(F)
1.2
(1.7)
1.9
(2.8)
2.2
(3.4)
3.0
(5.3)
3.0
(5.1)
3.9
(8.1)
150 N
(F)
3.2
(4.8)
5.0
(8.2)
6.0
(9.8)
8.2
(15.4)
11.0
(16.2)
12.8
(29.0)
Tab. 17
Venting time