MS6(N)-SV-...-E-ASIS
54
Festo – MS6(N)-SV-...-E-ASIS – 1205NH English
14.2
General data
Type
MS6-SV-…-E-ASIS
MS6N-SV-…-E-ASIS
Pneumatic connection 1, 2
G
½
(ISO 228)
NPT
½
-14
Pneumatic connection 3
G1 (ISO 228)
NPT1
Type of mounting
In-line installation
With accessories
Design
Piston seat not free of overlap
Actuation type
Electric
Pilot air supply
Internal
Exhaust function
Without flow control
Position sensing principle
Solenoid piston principle
Manual override
None
Reset method
Mechanical spring
Type of control
Piloted
Valve function
3/2-way valve, closed, monostable
Pressure build-up function
Mounting position
Any
Operating medium
Compressed air in accordance with
ISO 8573-1:2010 [7:4:4]
Note on operating medium
Operation with lubricated medium possible (required
for further operation)
Ambient temperature
[°C]
–10 … +50 (0 … +50 with pressure sensor)
Temperature of medium
[°C]
–10 … +50 (0 … +50 with pressure sensor)
Storage temperature
[°C]
–10 … +50 (0 … +50 with pressure sensor)
Shock resistance
Shock test with severity level 2 according to
FN 942017-5 and EN 60068-2-27
Vibration resistance
Transport application test with severity level 2 in ac-
cordance with FN 942017-4 and EN 60068-2-6
Operating pressure
[bar]
3.5 … 10
C value
[l/(s*bar)] 19.3
b value
0.21
Standard nominal flow rate
1
>
2
[l/min]
4 300 (if p1 = 6 bar, p2 = 5 bar)
Standard nominal flow rate
2
>
3
[l/min]
9 000 (if p1 = 6 bar)
Min. standard nominal flow rate
2
>
3 in the most critical error
case
[l/min]
6 000 (if p1 = 6 bar)
Residual pressure in normal op-
eration
[bar]
0 (no residual pressure)
Max. residual pressure in event
of error (worst case)
[bar]
0.4 (if p1 = 10bar and flow control valve is fully open)